Euroheat FB50 Скачать руководство пользователя страница 1

©

 

EUROHEAT

 

DISTRIBUTORS (H.B.S) LTD. Dec 2004

E & OE    Instructions Part number IN1084 Ed D

1

Installation and Servicing

Insert FB50 & FB80 Gas

Insert Conventional Flue

Serial Number

Part No.

Euroheat Distributors 

(H.B.S.) Ltd.,

Unit 2, Court Farm 

Business Park,

Bishops Frome,

Worcestershire,

WR6 5AY.

Содержание FB50

Страница 1: ...4 E OE Instructions Part number IN1084 Ed D 1 Installation and Servicing Insert FB50 FB80 Gas Insert Conventional Flue Serial Number Part No Euroheat Distributors H B S Ltd Unit 2 Court Farm Business Park Bishops Frome Worcestershire WR6 5AY ...

Страница 2: ...rt Aperture Construction 13 Housing construction when using an existing chimney breast 16 Construction by Modern Building Practices 17 Construction of surround in properties with a timber style construction 18 Special Insulation Requirements 19 Installation of Vent Duct Tubes 20 The Hearth and Fire Surround 21 Free Air and Vent Positioning 23 Fitting the Coal Effect 24 Gas Control Valve 24 Sit Gas...

Страница 3: ...Flame Yes Flame Failure Yes Fuel effect Coal Fuel outlet Top 100mm 4 Internal Diameter Warranty Standard 1 Year Gas Gas Pressure mbar Main Jet mm Maximum output Minimum output Low Burn Pilot Jet Hourly flow Burner pressure Hourly flow Low burn pressure G20H Natural Gas 20 1 jet with 4 x 0 96 0 64 m3 h 19mbar 0 32 m3 h 5 mbar 99 03 G31 LPG 37 1 jet with 4 x 0 65 0 49kg h 36mbar 0 26kg h 10mbar 98 29 ...

Страница 4: ...ar 0 33kg h 8 9mbar 98 24 1 2 Gas Pressure Maximum output Minimum output Hourly flow Hourly flow Low Burn By pass Jet Model Number 499944011 Heat Output Natural Gas 8kW 27 300BTU LP Gas 6 8kW 23 200BTU Gas Input Natural Gas 9 2kW 31 400BTU LP Gas 7 9kW 26 900BTU Heat Control Mertik Gas Valve Manual Control or Remote control option Sit Gas Valve eurosit 630 Manual and Thermostatic Fuel Types Natura...

Страница 5: ... e The installation must be in accordance with the Gas Safety Installation and Use Regulations 1994 andwiththeseinstructions andtherelevantpartsof the Localand National Building Regulations and the recommendations of the following British Standards BS 715 1993 Metal Flue Systems BS 1251 1987 Fireplace Components BS 1289 PT 1 1986 Flue Block Systems BS 5440 PT 1 1990 Flues BS 5440 PT 2 2000 Ventila...

Страница 6: ... a non combustible hearth The hearth must have a minimum of 12mm non combustible material thickness b The insert is not suitable for installation into a rear combustible wall any combustible materials must be removed from an area of 200mm around the installation of the appliance c There must be a minimum of 200mm from the top of the insert to the underside of any combustible shelf Note that for ev...

Страница 7: ...nd although they will reduce in temperature as the distance from the stove increases precautions should be taken to insulate them from combustible materials The front wall of the housing will be subject to both the heat of the convected air and the radiated heat from the fire Although the convected heat will be considerably reduced if the stove is utilizing its duct vents the front wall will inevit...

Страница 8: ...th heat vent pipes space C must be allowed for the vent pipe installation space C can be filled as required 7 Installation of the Flue System Refer to section 8 to determine which flue systems are suitable for your insert size having selected a suitable flue system please follow the applicable installation method Important in all installations the flue outlet of the appliance must be connected to the ...

Страница 9: ...entire length it need not be swept e Ensure that only one fireplace is served by the chimney or flue system f Ensure that the chimney or flue system is continuous from inlet to termination g Ensure that the chimney is structurally sound so the combustion products do not come into contact with combustible materials outside the chimney NOTE A guide is published by the British Flue and Chimney Manufactu...

Страница 10: ...o the current British Standards suitable for the fuel type of the appliance Flue liner supporting collar Cowl to prevent ingress of rain birds and or to assist with flue stabilization Fitted to a secure chimney pot Closure plate Ridged to flexible adapter on a solid fuel installation where the first section of flue pipe must be ridged This does not need to be ridged on a gas installation where the...

Страница 11: ...e surround a The final aperture opening will be dependant on the heat distribution method chosen The heat produced by the insert can either be directed completely through the appliance or partially vented to chamber above the stove and then into the room or partially vented to adjoining rooms by vent pipes 1 Full insert venting to room of installation 2 Venting by open chamber and insert convection...

Страница 12: ...e tubes must rise from the insert to there termination position Precautions must be made to prevent heat directed by these tubes from affecting inflammable materials Brass or steel hit and miss vent covers can be utilised to control heat output at the termination position CAUTION The exit point of these vents may become very hot and precautions should be taken to prevent injury by guarding The hit ...

Страница 13: ... much less than those of the ground floor Before removing any brickwork the covering plaster should be removed so that any lintels can be identified There will probably be two the first supporting a few courses of bricks above the fire back opening and a second higher up which may be in the form of arched brickwork or a reinforced concrete lintle which spreads the weight of the complete chimney struct...

Страница 14: ... or a proprietary non combustible board made for this purpose which closes all but a hole cut for the flue pipe of the chimney opening Its purpose is primarily to prevent the inevitable debre and especially lime mortar falling onto the stove top which will cause corrosive damage to the stove top but it also serves to position exactly the flue pipe in readiness for the stove If air ducts are to be at...

Страница 15: ...tect any pictures that may be hanging on them Because the flow of rising hot air from the stove front can be considerable and constantly changing in temperature no valuable pictures should be hung above the stove If a secondary lintel is to be fitted with only a single thickness of brick to be used as the closure the inner face of the bricks should be faced with insulation material to reduce the tem...

Страница 16: ...that anyone without the necessary experience constructs the housing and flue system for an insert stove Because the temperatures reached by the stove s top and side panels may reach over three hundred degrees Celsius all materials used for constructing the housing must be both non combustible stable at high temperatures and insulate any part of the building which may be affected by heat It should b...

Страница 17: ...e heat from the stove is transferred to the house wall Whilst this may sound daunting the reward will be a vast increase in heating efficiency One solution to the problem is to leave a space between the stove s housing back and the wall and provide ventilation to give an air flow between the two The housing should be constructed with insulating blocks such as Durarock and faced with brick or an insu...

Страница 18: ...the enclosure above the insert to become quite hot The level of temperature will vary greatly with the materials used In cases where non insulating materials are utilized we advise that insulation is incorporated as shown C D This is especially the case where brick or stone is used as a feature If the surround is to be plain we do not recommend the use of plaster board 11 Examples of Materials Bri...

Страница 19: ... or decorative grills are available for the outlets from builders merchants and architectural fitting suppliers Although the ducts should never become hot enough to cause a problem they should be protected from any combustible materials Where the ducts are to be taken into other rooms or floors consideration should be given to the fact that they will form a permanent passage for air to these rooms I...

Страница 20: ... fire surrounds of every possible style and material now abound but sadly not all are built to the highest standards or with materials best suited to the high temperatures they will be subjected to The minimum distances given in the drawing below will ensure the surround will be subjected to safe temperatures but it will not guarantee that a fire surround made from unseasoned wood will not shrink If...

Страница 21: ...al free air and flue termination trees cause wind turbulence to both the vent property is not symmetrical and especially so been added to the property or where nearby when an extension of a different height has ventilation is always more difficult when the The difficulty in providing consistent bushes garden buildings or other houses nearby property has no outside obstructions such as this duct Th...

Страница 22: ... vent area is not restricted and that the baffle is mounted securely and cannot be moved to restrict the vent This will only reduce the effects as it will not affect the air pressure only the air velocity Regular inspection must be carried out to ensure the vent does not become restricted Leaning a baffle plate against the vent or placing any un measured or movable object to restrict the vent eith...

Страница 23: ...n fitted as illustrated should give an even distribution of flames and allow the main body of coal to glow Because the loose coals are not uniform slight adjustment may be necessary to ensure no flames are directed towards the glass or impinge against the interior cast iron Any adjustments to the burner or coals must be made by the CORGI registered commissioning Front Coal Rear Coal Horse Shoe Coal S...

Страница 24: ...ent a see operating instructions for full details Ignition is by battery spark ensure battery is fitted Ensure control knob is in the off position Push in the control knob and turn to the pilot position keeping the knob depressed Press the ignition button The pilot should now be alight after the system has been purged Keep the knob depressed for 20 30 seconds when the knob is released the pilot sho...

Страница 25: ...ob for 30 seconds if the pilot has lit if it has not lit then repeat the pilot lighting procedure to maximum of 6 attempts If after 6 attempts the pilot has not ignited leave the appliance for 2 minutes before attempting again This assumes the system has been purged Once the pilot has been established let out the control knob and turn it anticlockwise to the ON position Manual Control Turn the lar...

Страница 26: ...ide of the front cover next to the on off knob push outwards and lift the cover off Pilot flame adjustment screw preset at factory Operating pressure adjustment screw The direction is indicated on the brass cover of the adjustment screw Insert a small screwdriver into slot lift outwards and lift cover off On Off Pilot Setting and Ignition Control Manual Control Front cover screw Low pressure adjus...

Страница 27: ...emote control receiver b 2 x small single wire connectors Fit to the micro switch c 2 x larger connectors fit to the motor Note these two connectors are different in size and fit only to the appropriate sized connector on the motor Receiver location Place the receiver out side the appliance away from heat Motor and Micro switch Gas Pressure Test Nipple Locations Line pressure test point Operating pr...

Страница 28: ...ctions Part number IN1084 Ed D 28 Removing Gas Burner Lift and remove coal support plate Loosen and disconnect gas supply pipe Remove burner retaining bolts When fitting main gas burner nozzle ensure sealing washes are fitted Main burner Jet Sealing Washer ...

Страница 29: ...e following procedure must be followed a The main burner nozzle must be changed to the required nozzle for the gas type to be used See appliance data b The pilot nozzle must be changed to the required nozzle for the gas type to be used c Eurosit 630 gas valve the low fire bypass nozzle in the gas control valve must be changed to the required nozzle for the gas type to be used See gas valve assembly...

Страница 30: ...essure is below requirements inspect gas pipe installation for possible problems e Ensure that all doors and windows in the room are shut light the insert and operate at maximum as per the recommended regulations During this operation a large amount of smoke will be produced as the paint surface cures Position a smoke match just above the furnace door and check that all the smoke is drawn into the...

Страница 31: ...that it is unaffected by currents of hot convecting air if spurious results are to be avoided The smoke match must not be held away from the outer frame or the currents of air passing upwards over the door will pull any smoke away from the dilution vent To test correctly the smoke match should be positioned inside the main frame of the appliance to be just in front of the dilution vent guard Note ...

Страница 32: ...e If there are any extractor fans in the room or adjacent rooms these must be running at maximum setting with all interconnecting doors left open and the spillage test repeated c Carry out a gas operating pressure test Attach a manometer to the operating pressure test nipple With the appliance operating at maximum observe the operating pressure Adjust if required d Carry out a low burn operating p...

Страница 33: ...d like a solid fuel stove ITS SURFACES BECOME VERY HOT f Do not use the appliance if the glass is craked or broken h Do not use the appliance if any of the coal effect components are broken i The appliance must be guarded to protect children the aged or infirm Euroheat Efel and Nestor Martin have a policy of continual research and development and reserve the right to modify its appliances without p...

Страница 34: ...Post Code Telephone Number Year 3 Annual Service Completed Date ___________ Parts Replaced Service Engineer House Name Number Street Name Locality Name Post Town County Post Code Telephone Number Year 4 Annual Service Completed Date ___________ Parts Replaced Service Engineer House Name Number Street Name Locality Name Post Town County Post Code Telephone Number Year 5 Annual Service Completed Dat...

Отзывы: