15
Troubleshooting Guide
Motor
Problem
Probable Case
Suggested Corrective Action
Motor does not start
1.Fuse
2.Brushes worn
3.Other
4.Low voltage
-15amp time delay fuse, or circuit breaker.
-See “Maintenance” section
-Check power supply for proper voltage and
Correct as needed
Brush sparking when switch
released.
1.Normal automatic brake working
properly
-None
Motor stalls easily
1.Low voltage
2.Excessive wheel pressure when
cutting
-Check power supply for proper voltage and
correct as needed
-Pull wheel through work at a slower pace
General
Problem
Probable Case
Suggested Corrective Action
Blade hits base or work
surface
1.Misalignment
2.Adjust down stop
-See “Alignment” section
Cut not square
1.Defecitive wheel
2.Work not positioned properly
3.Excessive wheel pressure
-Replace immediately
-Position work properly
-Lessen wheel pressure
Power head won’t fully rise or
blade guard won’t fully close
1.Lubrication needed
2.Part failure
3.Pivot spring or guard spring not
replaced properly after service
4.Dirt sticking to stops
-See “Lubrication” section
-Inspect/clean stops
Blade binds, jams, burns
workpiece.
Rough cuts
1.Improper operation
2.Dull blade
3.Improper blade
-See “Basic Saw Operation” section
-Replace or sharpen wheel
-Replace with 14” diameter wheel designed for the
material being cut
Tool vibrates or shakes
1.Sawblade not round
2.Sawblade damaged
3.Sawblade loose
4.Other
-Replace wheel
-Replace wheel
-Tighten arbor screw
Power head hard to pull/push
down
1.Lube needed
-See- “Lubrication” section
NOISE
A-weighted sound pressure level measuring under load
51306 :Position 1-5 Lp,eq =92.2 dB(A)
51306-1:Position 1-5 Lp,eq =94.4 dB(A)
A-weighted sound power level measuring under load
51306 :Calculated Lw,eq = 103.5dB(A)
51306-1:Calculated Lw,eq = 105.1dB(A)
Содержание EDC.135
Страница 1: ...Manual EDC 135 Sawing Machine ...