INSTALLATION PERSONNEL

This appliance shall be installed only by authorised

persons and in accordance with the manufacturer's

installation instructions, local gas fitting regulations,

municipal  building  codes,  electrical  wiring

regulations, AS 5601/AG 601 - Gas Installations and

any other statutory regulations.

The wall and bench surfaces must be capable of

sustaining temperatures of 75 degrees Celsius.

All laminates, fixing adhesive and surfacing materials

should be certified suitable for this temperature.

Any adjoining wall surface situated within 200 mm from

the edge of any hob burner must be a suitable non-

combustible material for a height of 150 mm for the entire

length of the hob. Any combustible construction above the

hotplate must be at least 650 mm above the top of the

burner and no construction shall be within 450 mm above

the top of the burner. A minimum depth of 60 mm from the

top of the worktop surface must be provided for the

appliance.

3) INSTALLING THE HOT PLATE

Check that the appliance is in a good condition after

having removed the outer packaging and internal

wrappings from around the various loose parts. In

case of doubt, do not use the appliance and contact

qualified personnel.

Never leave the packaging materials (cardboard,

bags, polystyrene foam, nails, etc.) within

children’s reach since they could become

potential sources of danger.

The measurements of the opening made in the top

of the modular cabinet and into which the hot plate

will be installed are indicated in fig. 7.

Always comply with the measurements given for the

hole into wich the appliance will be recessed (see

fig. 7).

The  appliance  belongs  to  class  3  and  is

therefore  subject  to  all  the  provisions

established by the provisions governing such

appliances. 

INSTALLATION

FIG. 7

COMPLY WITH THE DIMENSIONS (mm)

A

B

C

D

E

4F- 5F (860)

833

475

62.5

62.5 73.5 min.

IMPORTANT: 

a  perfect  installation,  adjustment  or

transformation of the cook top to use other

gases requires a QUALIFIED INSTALLER: a

failure  to  follow  this  rule  will  void  the

warranty.

Содержание EGZ900WWFSX

Страница 1: ...cts themselves If your cooktop requires service please contact your local customer service centre or your nearest Eurostyle agent listed at the back of this booklet COD 04031HM 11 05 2012 Dear Custome...

Страница 2: ...2 MJ 4 Cast iron pan support 1F 5 Cast iron pan support 2F 6 Burner n 1 control knob 9 Burner n 2 control knob 10 Burner n 3 control knob Attention this appliance has been manufactured for domestic us...

Страница 3: ...duced rate position small flame fig 1 Always place a lid on the pans Use only pan with a flat bottom and in thick metal WARNINGS burners with flame failure device may only be ignited when the relative...

Страница 4: ...less especially for children who might play on an abandoned appliance Do not touch the appliance with wet or damp hands or feet Do not use the appliance barefoot The manufacturer will not be liable fo...

Страница 5: ...e the taps if they are difficult to open or close Contact the technical assistance service for repairs Don t use steam jets for cleaning the cooktop CARE MAINTENANCE To optimize the appearance and up...

Страница 6: ...of the worktop surface must be provided for the appliance 3 INSTALLING THE HOT PLATE Check that the appliance is in a good condition after having removed the outer packaging and internal wrappings fro...

Страница 7: ...ngers and remove the strip of protective paper from the seal and set the plate into the hole made in the cabinet Fix the hob with the proper brackets S and fit the prominent part into the porthole H o...

Страница 8: ...n point is accessible with the appliance installed Warning ensure that the hose assembly is restrained from accidental contact with the flue or flue outlet of an underbench oven Natural Gas Natural Ga...

Страница 9: ...connected to the electricity main by a socket Fit a standard plug suited to the load indicated on the data label to the cable Fit the wires following figure n 12 B taking care of respecting the follow...

Страница 10: ...erate correctly after all checks have been carried out refer to the authorised service provider in your area 7 TAPS Our taps are suitable for all the gas they are male conical type at one way Reduced...

Страница 11: ...ar the gas connection 12 Fit the new data label included in the gas conversion kit 9 NATURAL GAS TO U LPG CONVERSION PROCEDURE 1 Remove each burner cap and burner skirt 2 Remove the Natural Gas main i...

Страница 12: ...ned in paragraphs 7 The technician must reset any seals on the regulating or pre regulating devices The envelope with the injectors and the labels can be included in the kit or at disposal to the auth...

Страница 13: ...al D each time a tap is changed in order to ensure a perfect tightness Greasing the taps see fig 19 20 If a tap becomes stiff to operate it must be immediately greased in compliance with the following...

Страница 14: ...PLY CABLE TYPES AND SECTIONS ATTENTION If the power supply cable is replaced the installer should leave the ground wire longer than the phase conductors fig 21 and comply with the recommendations give...

Страница 15: ...or our nearest After Sales Service Center whenever repairs or adjustments are required specifying the type of fault and the model of the appliance in your possession Please also note that genuine spa...

Страница 16: ...16...

Отзывы: