background image

11

8) U-LPG TO NATURAL GAS

CONVERSION PROCEDURE

1.

Remove each burner cap and burner skirt.

2.

Remove  the  U-LPG  main  injector  with  a

7 mm/VF tube spanner and replace with the

appropriate size Natural Gas main injector for each

burner. The following injector sizes are required for

Natural Gas:

Burner

Main injector

Wok

1.76  mm

Semi Rapid

1.20  mm

Rapid        

1.55  mm

3.

Shut off gas supply to the appliance.

4.

Disconnect gas inlet pipe from the U-LPG test

point inlet fitting.

5.

Remove the U-LPG test point inlet fitting from

the appliance.

6.

Fit the Natural Gas Regulator supplied in the

conversion kit.

7.

Connect the gas supply to the Regulator.

8.

Check for gas leaks. Do not use a naked flame

to check for gas leaks.

9.

Adjust the gas pressure to 1.00 kPa.

10.

Remove the control knob, with a thin shaft blade

screwdriver down the centre of each gas valve

shaft, screw the by-pass injector anti-clockwise.

Test the appliance on both high and low flame for

each burner. If the burner fails to remain alight or

the flame is not stable on the simmer setting, adjust

the by-pass screw, until flame is stable.

11.

If not already removed, remove the “Only for

use with U-LPG” label adhered to the bottom panel

near the gas connection.

12.

Fit the new data label included in the gas

conversion kit.

9) NATURAL GAS TO U-LPG

CONVERSION PROCEDURE

1. 

Remove each burner cap and burner skirt.

2.

Remove the Natural Gas main injector with a

7 mm/VF tube spanner and replace with the

appropriate size U-LPG main injector for each

burner. The following injector sizes are required for

U-LPG:

Burner

Main injector

Wok

0.94  mm

Semi Rapid

0.70  mm

Rapid        

0.91   mm

3. 

Remove the control knob, with a thin shaft blade

screwdriver down the centre of each gas valve

shaft, screw the by-pass injector fully clockwise.

4.

Shut off gas supply to the appliance.

5.

Disconnect gas inlet pipe from the Natural Gas

Regulator.

6.

Remove the Natural Gas Regulator from the

appliance.

7.

Fit the U-LPG test point inlet fitting supplied in

the conversion kit.

8.

Connect the gas supply to the inlet fitting.

9.

Check for gas leaks. Do not use a naked flame

to check for gas leaks.

10.

Adjust the gas pressure to 2.75 kPa.

11.

Test the appliance on both high and low flame

for each burner and check the gas pressure. If the

burner fails to remain alight or the flame is not

stable on the simmer setting, adjust the by-pass

screw until flame is stable.

12.

If not already removed, remove the “Only for

use with Natural Gas” label adhered to the bottom

panel near the gas connection.

13.

Fit the new data label included in the gas

conversion kit.

CONVERSIONS

Содержание EGZ900WWFSX

Страница 1: ...cts themselves If your cooktop requires service please contact your local customer service centre or your nearest Eurostyle agent listed at the back of this booklet COD 04031HM 11 05 2012 Dear Custome...

Страница 2: ...2 MJ 4 Cast iron pan support 1F 5 Cast iron pan support 2F 6 Burner n 1 control knob 9 Burner n 2 control knob 10 Burner n 3 control knob Attention this appliance has been manufactured for domestic us...

Страница 3: ...duced rate position small flame fig 1 Always place a lid on the pans Use only pan with a flat bottom and in thick metal WARNINGS burners with flame failure device may only be ignited when the relative...

Страница 4: ...less especially for children who might play on an abandoned appliance Do not touch the appliance with wet or damp hands or feet Do not use the appliance barefoot The manufacturer will not be liable fo...

Страница 5: ...e the taps if they are difficult to open or close Contact the technical assistance service for repairs Don t use steam jets for cleaning the cooktop CARE MAINTENANCE To optimize the appearance and up...

Страница 6: ...of the worktop surface must be provided for the appliance 3 INSTALLING THE HOT PLATE Check that the appliance is in a good condition after having removed the outer packaging and internal wrappings fro...

Страница 7: ...ngers and remove the strip of protective paper from the seal and set the plate into the hole made in the cabinet Fix the hob with the proper brackets S and fit the prominent part into the porthole H o...

Страница 8: ...n point is accessible with the appliance installed Warning ensure that the hose assembly is restrained from accidental contact with the flue or flue outlet of an underbench oven Natural Gas Natural Ga...

Страница 9: ...connected to the electricity main by a socket Fit a standard plug suited to the load indicated on the data label to the cable Fit the wires following figure n 12 B taking care of respecting the follow...

Страница 10: ...erate correctly after all checks have been carried out refer to the authorised service provider in your area 7 TAPS Our taps are suitable for all the gas they are male conical type at one way Reduced...

Страница 11: ...ar the gas connection 12 Fit the new data label included in the gas conversion kit 9 NATURAL GAS TO U LPG CONVERSION PROCEDURE 1 Remove each burner cap and burner skirt 2 Remove the Natural Gas main i...

Страница 12: ...ned in paragraphs 7 The technician must reset any seals on the regulating or pre regulating devices The envelope with the injectors and the labels can be included in the kit or at disposal to the auth...

Страница 13: ...al D each time a tap is changed in order to ensure a perfect tightness Greasing the taps see fig 19 20 If a tap becomes stiff to operate it must be immediately greased in compliance with the following...

Страница 14: ...PLY CABLE TYPES AND SECTIONS ATTENTION If the power supply cable is replaced the installer should leave the ground wire longer than the phase conductors fig 21 and comply with the recommendations give...

Страница 15: ...or our nearest After Sales Service Center whenever repairs or adjustments are required specifying the type of fault and the model of the appliance in your possession Please also note that genuine spa...

Страница 16: ...16...

Отзывы: