158
NOTE
□
The output port in the closed state has no current limiter, the user
circuit must be designed to avoid excessive currents that could destroy
the output port.
□
The output port remains in the OFF-state until it is under control of the
application.
AC characteristics
Parameter
Min. Typ. Max. Units
Pulse rate
0
100
kHz
Turn-on time
5
µs
Turn-off time
5
µs
Typical switching performance @ 25°C
Current [mA]
Turn ON time [µs]
Turn OFF time [µs]
0.5
2.0
4.8
1.0
2.0
3.9
4.0
2.2
3.3
10
2.3
2.7
40
2.3
2.7
100
2.3
2.7
Isolation characteristics
Parameter
Value
Isolation grade
Functional
Max. DC voltage
250 V
Max. AC voltage
170 V
RMS
NOTE
The functional isolation is only for the circuit technical protection. It does not
provide an isolation that can protect a human being from electrical shock!
Coaxlink
Hardware Manual