143
DC characteristics
Parameter
Conditions
Min. Typ. Max.
Units
ESD protection Human Body Model (HBM)
2
kV
NOTE
The I/O port includes a latch-up protection.
Driver
Parameter
Conditions
Min. Typ. Max.
Units
Low-level output current
64
mA
Low-level output voltage
@ 8 mA
0.34
0.36
V
@ 16 mA
0.48
0.55
V
@ 32 mA
0.78
0.81
V
@ 64 mA
1.34
1.36
V
High-level output current
-32
mA
High-level output voltage
@-8 mA; (1)
2.60
3.00
V
@-16 mA; (1)
2.20
2.70
V
@-32 mA; (1)
1.75
2.20
V
ESD protection
Human Body Model (HBM)
2
kV
Condition (1)
: 300 Ohms line termination resistor to GND.
Receiver
Parameter
Conditions Min. Typ. Max.
Units
Absolute maximum voltage rating
0
5
V
Coaxlink
Hardware Manual