126
Requirements for PEG connector
The network is fed by a 12 V external power supply attached to the auxiliary power input
connector using a power cable terminated by a 6-pin PEG plug connector. A protection fuse
inserted at the input side prevents potential fire hazards.
Parameter
Min. Typ. Max. Units
Voltage
11.0
12.0
13.0
V
WARNING
On the card side of the power cable, check carefully the voltage on each pin
of the 6-pin PEG connector plug before insertion!
See also:
"Avoid Mixing Power Supply Cables" on page 234
Requirements (MOLEX connector)
The network is fed by a 24 V external power supply attached to the auxiliary power input
connector using a power cable terminated by a 4-pin MOLEX plug connector. A protection fuse
inserted at the input side prevents potential fire hazards.
Parameter
Min. Typ. Max. Units
Voltage
23
24
25
V
WARNING
On the card side of the power cable, check carefully the voltage on each pin
of the 4-pin Molex connector plug before insertion!
See also:
"Avoid Mixing Power Supply Cables" on page 234
Monitoring the auxiliary power input
The
AuxiliaryPower12VInput
GenApi feature of the Interface module reports the status of the "12V
Auxiliary Power Input" measured after the input fuse.
The
AuxiliaryPowerInput
GenApi feature of the Interface module reports the status of the
auxiliary power input cable connection. This feature is only available for products having a PEG
connector with a
SenseIN
input.
NOTE
The
SenseIN
input of the PEG connector is used for power source cable
presence detection. It should be grounded at the power supply level.
Coaxlink