background image

- 10 -

Installation Procedure of

Model : Aquaguard

®

 Universa 80SC

The Universa 80SC is a standalone with floor installation, Discuss with the customer and 

finalizes the place for install the unit. The preferable place is to position the product is 

somewhere near to the drain point and closure to the electrical socket. Then follow the 

below procedure for installation:

Diverter valve fixing: 
1. Close the input source valve for the water pipe line where the purifier is planned to  

 

be installed. 

2.  

Remove the existing tap from location where the unit is planned to be installed. 

3.  

Connect the Diverter valve to the point and fix the existing tap to the Diverter valve. 

4.  

Check for water leakage from the joints. 

Flushing the unit: 

1.  

Make the product to standalone on the platform with the help of leg bush. 

2.  

Connect the other end of the PL8 tube white (connected to the diverter valve) to the  

 

inlet of the product & Remove the Flush port dummy plug from the bottom. 

3.  

Connect the PL4 tube blue to the Flush port of the product and leave the other end  

 

into drain. 

CAUTION: Sediment Filter & Carbon Cartridge should be flush for minimum of 5 to 10 

minutes before connection to the unit. 
4.  

After flushing close the DV & remove the all the tubes form the inlet & flush port, the  

 

replace the dummy plug in the flush port.

 Ø

  Connect the PL8 white color tube to the quick connector which is fixed on the

 diverter 

valve.

 Ø

 Connect the other end of the PL8 tube to the inlet port of the purifier.

 Ø

 Connect the blue colour tube to the drain port and place the other end of the tube in  

 

to the drain point where draining facility is available. Ensure that the tube does not  

 

come out from the drain point.

Содержание Aquaguard Pro Universa 80SC

Страница 1: ...Read this manual carefully before using the water purifier ...

Страница 2: ... 80SC RO UV Storage Cooler Cum Purifier Aquaguard Universa 80SC is a 7 stage online Reverse Osmosis and Ultra Violet based water purifier with Storage Tank The Product has a Storage Capacity of 80 Ltr And the refrigeration system capacity of 60 Ltr At 17 C 1 C water dispensing It has 3 advanced operating modes RO UV UV Auto Mode In Auto Mode It automatically switches between RO UV or UV technologi...

Страница 3: ... the input water Reverse Osmosis Membrane Filter Purification stage 5 Reverse Osmosis Membrane filter has a porosity of 0 0001 micron and strains the micro organism TDS Total Dissolved Solids from the input water This stage rejects around 90 of the input TDS and the permeate water purified good water flows towards the next stage Post Carbon Cartridge Purification stage 6 This process enhances the ...

Страница 4: ...des mg lit max Requirement Desirable Limits IS 10500 1991 300 500 0 3 250 45 1 0 001 0 05 0 05 0 001 Harmful Effects Produced When Chemical Constituents Exceed Desirable Limits Formation of a white layer on the surface of water supply structures and adverse effects on water usage for domestic purposes Beyond this limit palatability decreases and may cause gastrointestinal irritation Beyond this li...

Страница 5: ...GPD Permeate Purified Water Production Capacity 50 LPH of Purified Water Recovery 25 Rejection of TDS 90 Approx Eg if Input Water Contains 1000mg Ltr The Output Water Contains TDS up to 100mg Ltr Storage Tank Material SS 304 Outer Body Material SS 304 Type of Product Construction Concealed Type of Installation Indoor Weight 86 Kg Input Water Conditions Minimum Input Water Pressure 1 Kg Sq cm Recom...

Страница 6: ... FILTER 10 MEMBRANE LIFE ENHANCER CHECK VALVE FLOW SENSOR CHECK VALVE 3 8 LOW PRESSURE SWITCH AQUAGUARD UNIVERSA 80SC POST CARBON 11 W REFLECTOR HOUSING CHECK VALVE PL 8 HIGH PRESSURE SWITCH Tap1 Tap2 UV LAMP QG TUBE 1 QG TUBE 2 PUMP 1 PUMP 2 75 GPD RO MEMBEANE 1 TEE 3 8 4 1 E E T 4 1 x 4 1 x 8 3 E E T TEE 1 4 x1 4 x3 8 8 3 E E T 4 1 x 8 3 x 8 3 E E T TEE 3 8 TANK 80 Lts BLENDING SV PL 3 8 TDS SEN...

Страница 7: ... 7 WIRING DIAGRAM UNIVERSA 80SC WIRING DIAGRAM ...

Страница 8: ...and water borne micro organisms during the process Ø Safe drinking water is assured at the outlet using the advanced internationally proven UV technology leaving no chance for re contamination Ø No need for bottled water Ø Self Cleaning System This ensures superior and effective membrane performance by auto flushing every 4 hour Ø Tough Hygienic and Durable Body Aquaguard Universa 80SC is unique i...

Страница 9: ...nit by yourself This may lead to total system failure and even death If the unit is not working inform the Do not install the unit in direct and diffused nearest customer response center sun light Connect the unit to duly grounded Do not keep any objects above the unit 230VAC 15A power supply Ensure replacing the filters as per Do not keep the unit open the frequency mentioned in the replacements ...

Страница 10: ...oduct to standalone on the platform with the help of leg bush 2 Connect the other end of the PL8 tube white connected to the diverter valve to the inlet of the product Remove the Flush port dummy plug from the bottom 3 Connect the PL4 tube blue to the Flush port of the product and leave the other end into drain CAUTION Sediment Filter Carbon Cartridge should be flush for minimum of 5 to 10 minutes...

Страница 11: ...alve Water Not Coming opened No water supply Ensure continuous water supply Blockage in the Clear the blockage water line Back flush the sediment filter candle Sediment filter candle If it is still blocked contact nearest is blocked customer Response centre for replacement Carbon filter is blocked Inform the nearest customer response centre Water Flow Rate is SV malfunctioning Inform the nearest c...

Страница 12: ...f goods thereafter 3 The Company or it Authorised Distributor will be entitled to retain any defective part replaced under the warranty 4 The Company s liability under the Warranty will be limited only to defects which occur under the conditions of normal operations and under proper use It excludes defects occurring because of abuse faulty care or maintenance repairs alterations to goods or partly...

Страница 13: ...e operation or maintenance or repairs alterations to the Goods or any part thereof by others or the use of the Goods on electrical supply for which they are not designed or damage caused by lighting or other electrical disturbances or interruptions c The Company s liability under this Warranty shall remain valid only if the Goods are duly installed by the Company or its authorized agent at the loc...

Страница 14: ...B1 B2 Marathon Innova Off Ganpatrao Kadam Marg Lower Parel Mumbai 400 013 Tel No 022 30449700 Fax No 30434970 ...

Отзывы: