AQUAGUARD
®
ASTOR RO+UV+MTDS+ALKALINE
TECHNICAL SPECIFICATIONS*
Aquaguard
®
Astor RO+UV+MTDS+ALKALINE
Model
2.
Dimension (WXDXH)
320 mm X 275 mm X 476 mm
Net Weight
7 KG (Approx.)
3.
Purification Technology
RO+UV+MTDS+ALKALINE
6 Litres (Approx.)
4.
Tank Capacity
i-Filter™, Chemi-Block, Reverse Osmosis (RO) Membrane,
TDS Regulator (MTDS), UV e-boiling
TM
, Alkaline Cartridge
5.
Purification Stages
1.
1.
Power Rating
40 Watts (Max.)
1.
UV Lamp
4 Watts
3.
UV Lamp LIFE
5,000 Burning Hours (As Per UV Lamp Manufacturer Spec.)
4.
Operating Voltage Range
150 to 250 VAC, 50 HZ
5.
Solenoid Valve
24 V DC
6.
Power Supply
Input 230VAC, 50Hz. Output 24V, (On Board AC-DC)
2.
ELECTRICAL SPECIFICATIONS
Input Iron (Max.) 0.3 mg/L
2.
Total Dissolved Solids
+
(TDS) (Max.)
Up to 2,000 mg/L
++
5.
Input Water Temperature
Range
10°C to 40°C
6.
Input Chlorine Content
(Max.)
0.2 mg/L
3.
Input Water Turbidity
(Max.)
5 NTU
4.
Input Water Pressure
Range**
0.3 to 3 kg/cm
2
1.
RECOMMENDED INPUT WATER PARAMETERS
PRODUCT SPECIFICATIONS
CARTRIDGE LIFE
Note: Please refer Standard Test Conditions
#
and Standard Test Condition for Alkaline Cartridge
##
for filter life. **As per manufacturer's spec.
For Aquaguard
®
Astor RO+UV+MTDS+ALKALINE
Consumable Cartridges
i-Filter™
Chemi-Block
Alkaline Cartridge
UV Lamp (4W) (RO+UV+MTDS)
RO Membrane
Average Service Life
6,000
#
Litres
6,000
#
Litres
6,000
#
Litres
5,000 Burning Hours**
6,000
#
Litres
CLEANING AND DISINFECTION OF
WATER STORAGE TANK
Note:
Storage Tank of this product must be periodically cleaned (at least once in every 30 days) by
a disinfectant. Disinfection Tablet* may be purchased from the Company Authorised Service
Centre. Please follow the disinfection process strictly as per the instructions as provided in this User
Manual.
• Drain the tank completely.
• Switch OFF the water purifier from the main power supply.
• Open the top cover, wipe the inside of the tank with a dry, clean soft cloth.
• Keep the top cover in place.
• Switch the power supply ON.
• Let the storage tank get filled & then drop one disinfection tablet* into the tank.
Caution: Keep the Disinfection Tablet* out of the reach of children.
Do not eat/consume the tablet.
• Keep the top cover in place & leave the unit for 30 mins.
• After 30 mins. open the tap & discard this and the first filling water completely.
• Now your unit is ready to use. In case you notice any medicinal taste/smell, discard the tank
of water fully & let it refill again.
• Please ensure that this disinfection process is carried out by the authorised installation
person/service technician during first installation and in every subsequent mandatory servicing
of your product.
*Available with Eureka Forbes Service Technician.
A QUICK CHECKLIST
Water is
leaking
Water tastes
bad
1. Is the tank clean?
2. Have you kept the purified
water in the tank for too
long?
3. Is it time to change the
filter?
1. Clean the storage tank.
2. Dispose the water and clean the tank.
3. Call an authorised Eureka Forbes
service technician.
Less water has
been purified
1. Is the tap water valve
closed?
2. Is the tap water pressure
too low?
3. Filters may be clogged or
damaged?
1. Open the tap water valve.
2. If so, the amount of purified water will
be reduced.
3. Call an authorised Eureka Forbes
service technician.
1. Is water coming out of
the top of the purifier?
Water doesn't
flow into the
storage tank
1. Is there water available in
the overhead tank?
2. Is the main water supply
tap closed?
3. Not sure what is wrong?
1. Ensure the overhead tank is filled with
water.
2. Ensure the tap is open.
3. Call an authorised Eureka Forbes
service technician.
1. Close the tap water valve, unplug the
power cord and call an authorised
Eureka Forbes service technician.
Problems
Checkpoints
Solutions
TIPS FOR SAFETY AND MAINTENANCE OF
YOUR AQUAGUARD
®
• Read attentively and understand the purifier and its functions, before use.
• Installation and service has to be conducted by authorised person from
Eureka Forbes Limited only.
• In case of any damage or incorrect functioning, immediately contact an authorised service
centre of Eureka Forbes Limited.
• Water from waste water tube is not suitable for drinking. You can use that water for gardening
or to clean floors (For applicable models only).
• Water storage tank must be periodically (at least once in every 30 days) cleaned using
a disinfectant (For applicable models only).
• Drain the water if it hasn’t been used for over 48 hours.
• Ensure that the flow restrictor is checked and replaced (if required), by the authorised service
technician during the mandatory service or in-service call (For applicable models only).
• Ensure that the replacement of the consumable cartridges are done by a trained
Eureka Forbes technician.
• Ensure that the filter cartridges and spares used during service/replacement are genuine and
from Eureka Forbes Limited only.
*Technical Specifications are subject to change without prior notice.
+
As input water applicable to the overall
product.
Note: The performance data presented in the table is applicable under standard laboratory conditions
#
. Actual
performance may vary depending on the input water quality, water pressure, turbidity and condition of filters. Input
water quality/pressure/TDS are important determinants of recovery rate and rejection.
**If the input water pressure is more than 3.0 kg/cm
2
, installation of a PRV (Pressure Reducing Valve) is
mandatory. If the input water pressure is less than 0.3 kg/cm
2
, installation of a booster pump is recommended. If
the input water pressure is less than 0.3 kg/cm
2
, installation of a booster pump is recommended.
++
If the input water TDS is more than 1,000 ppm (mg/L) or input water hardness is more than 300 ppm (mg/L), use
of a Membrane life enhancer is recommended.
These accessories are available at an extra cost.
Warranty void if not installed as per recommendations.
#
Standard Test Conditions:
Feed Water Quality: TDS Max: 1,000 mg/L with NaCl, Pressure: 1 kg/cm
2
, Turbidity: 1
NTU (Max.), Temperature: 25°C, Chlorine: Below 0.2 mg/L, Iron: Below 0.3 mg/L Life: 6,000 Litres.
##
Standard test conditions of Alkaline Cartridge Input water:
pH : 7.0 (+/- 0.2); TDS : 40 (+/- 10 mg/l); Flow
rate: 250 ml/min; Temperature: 25ºC.
Under standard test conditions
##
, the output water pH range is 7.5 – 8.5 (+/- 0.2).
Note : Performance of alkaline cartridge is applicable under standard test conditions of Alkaline cartridge
##
. Actual
performance may vary depending on the input water quality, life of alkaline cartridge & RO membrane element.
Under certain input water quality condition the pH of output water from alkaline cartridge can exceed 8.5 pH."