background image

AQUAGUARD

®

 ASTOR RO+UV+MTDS+ALKALINE

TECHNICAL SPECIFICATIONS* 

Aquaguard

®

 Astor RO+UV+MTDS+ALKALINE

Model

2.

Dimension (WXDXH)  

320 mm X 275 mm X 476 mm

Net Weight

7 KG (Approx.)

3.

Purification Technology

RO+UV+MTDS+ALKALINE

6 Litres (Approx.)

4.

Tank Capacity 

i-Filter™, Chemi-Block, Reverse Osmosis (RO) Membrane,

TDS Regulator (MTDS), UV e-boiling

TM

, Alkaline Cartridge

5.

Purification Stages

1.

1.

Power Rating

40 Watts (Max.)

1.

UV Lamp

4 Watts

3.

UV Lamp LIFE

5,000 Burning Hours (As Per UV Lamp Manufacturer Spec.)

4.

Operating Voltage Range

150 to 250 VAC, 50 HZ

5.

Solenoid Valve

24 V DC

6.

Power Supply

Input 230VAC, 50Hz. Output 24V, (On Board AC-DC) 

2.

ELECTRICAL SPECIFICATIONS

Input Iron (Max.)                           0.3 mg/L

2.

Total Dissolved Solids

+

 

(TDS) (Max.) 

Up to 2,000 mg/L

++    

5.

Input Water Temperature

Range

10°C to 40°C

6.

Input Chlorine Content 

(Max.)                           

0.2 mg/L

3.

Input Water Turbidity 

(Max.)

5 NTU

4.

Input Water Pressure 

Range**

0.3 to 3 kg/cm

2

1.

RECOMMENDED INPUT WATER PARAMETERS

PRODUCT SPECIFICATIONS

CARTRIDGE LIFE

Note: Please refer Standard Test Conditions

#

 and Standard Test Condition for Alkaline Cartridge

##

 

for filter life. **As per manufacturer's spec.

For Aquaguard

®

 Astor RO+UV+MTDS+ALKALINE

Consumable Cartridges 

i-Filter™

Chemi-Block 

Alkaline Cartridge

UV Lamp (4W) (RO+UV+MTDS)

RO Membrane

Average Service Life

6,000

#

 Litres

6,000

#

 Litres

6,000

#

 Litres

5,000 Burning Hours** 

6,000

#

 Litres

CLEANING AND DISINFECTION OF 

WATER STORAGE TANK

Note: 

Storage Tank of this product must be periodically cleaned (at least once in every 30 days) by 

a disinfectant. Disinfection Tablet* may be purchased from the Company Authorised Service 
Centre. Please follow the disinfection process strictly as per the instructions as provided in this User 
Manual.
•  Drain the tank completely. 

•  Switch OFF the water purifier from the main power supply.

•  Open the top cover, wipe the inside of the tank with a dry, clean soft cloth.

•  Keep the top cover in place.

•  Switch the power supply ON. 

•  Let the storage tank get filled & then drop one disinfection tablet* into the tank.

   Caution: Keep the Disinfection Tablet* out of the reach of children. 
   Do not eat/consume the tablet.

•  Keep the top cover in place & leave the unit for 30 mins.

•  After 30 mins. open the tap & discard this and the first filling water completely. 

•  Now your unit is ready to use. In case you notice any medicinal taste/smell, discard the tank
   of water fully & let it refill again.

•  Please ensure that this disinfection process is carried out by the authorised installation
   person/service technician during first installation and in every subsequent mandatory servicing
   of your product.

*Available with Eureka Forbes Service Technician.

A QUICK CHECKLIST

Water is 

leaking

Water tastes 

bad 

1. Is the tank clean? 

2. Have you kept the purified 

    water in the tank for too 

    long? 

3. Is it time to change the 

    filter? 

1. Clean the storage tank. 

2. Dispose the water and clean the tank.

3. Call an authorised Eureka Forbes 

    service technician.

Less water has

been purified 

1. Is the tap water valve 

    closed? 

2. Is the tap water pressure 

    too low? 

3. Filters may be clogged or 

    damaged?

1. Open the tap water valve. 

2. If so, the amount of purified water will 

    be reduced. 

3. Call an authorised Eureka Forbes 

    service technician.

1. Is water coming out of 

    the top of the purifier?

Water doesn't

flow into the

storage tank 

1. Is there water available in 

    the overhead tank? 

2. Is the main water supply 

    tap closed? 

3. Not sure what is wrong?

1. Ensure the overhead tank is filled with 

    water. 

2. Ensure the tap is open.

3. Call an authorised Eureka Forbes 

    service technician.

1. Close the tap water valve, unplug the 

    power cord and call an authorised

    Eureka Forbes service technician.

Problems 

Checkpoints 

Solutions

TIPS FOR SAFETY AND MAINTENANCE OF 

YOUR AQUAGUARD

®

• Read attentively and understand the purifier and its functions, before use.
• Installation and service has to be conducted by authorised person from 
  Eureka Forbes Limited only.
• In case of any damage or incorrect functioning, immediately contact an authorised service
  centre of Eureka Forbes Limited.
• Water from waste water tube is not suitable for drinking. You can use that water for gardening
   or to clean floors (For applicable models only).
• Water storage tank must be periodically (at least once in every 30 days) cleaned using
  a disinfectant (For applicable models only).
• Drain the water if it hasn’t been used for over 48 hours.
• Ensure that the flow restrictor is checked and replaced (if required), by the authorised service
  technician during the mandatory service or in-service call (For applicable models only).
• Ensure that the replacement of the consumable cartridges are done by a trained
  Eureka Forbes technician. 
• Ensure that the filter cartridges and spares used during service/replacement are genuine and  
   from Eureka Forbes Limited only.

*Technical Specifications are subject to change without prior notice. 

+

As input water applicable to the overall 

product.

Note: The performance data presented in the table is applicable under standard laboratory conditions

#

. Actual 

performance may vary depending on the input water quality, water pressure, turbidity and condition of filters. Input 

water quality/pressure/TDS are important determinants of recovery rate and rejection.

**If the input water pressure is more than 3.0 kg/cm

2

, installation of a PRV (Pressure Reducing Valve) is 

mandatory. If the input water pressure is less than 0.3 kg/cm

2

, installation of a booster pump is recommended. If 

the input water pressure is less than 0.3 kg/cm

2

, installation of a booster pump is recommended.

 

++

If the input water TDS is more than 1,000 ppm (mg/L) or input water hardness is more than 300 ppm (mg/L), use 

of a Membrane life enhancer is recommended. 

These accessories are available at an extra cost.

Warranty void if not installed as per recommendations.

#

Standard Test Conditions: 

Feed Water Quality: TDS Max: 1,000 mg/L with NaCl, Pressure: 1 kg/cm

2

, Turbidity: 1 

NTU (Max.), Temperature: 25°C, Chlorine: Below 0.2 mg/L, Iron: Below 0.3 mg/L Life: 6,000 Litres.

##

Standard test conditions of Alkaline Cartridge Input water:

 pH : 7.0 (+/- 0.2);  TDS : 40 (+/- 10 mg/l); Flow 

rate: 250 ml/min; Temperature: 25ºC.

Under standard test conditions

##

, the output water pH range is 7.5 – 8.5 (+/- 0.2).

Note : Performance of alkaline cartridge is applicable under standard test conditions of Alkaline cartridge

##

. Actual 

performance may vary depending on the input water quality, life of alkaline cartridge & RO membrane element. 

Under certain input water quality condition the pH of output water from alkaline cartridge can exceed 8.5 pH."

Отзывы: