EUCHNER TQ Series Скачать руководство пользователя страница 6

6

Operating Instructions

Safety Switch TQ…

Actuating auxiliary release

Screwdriver

Figure 2:  Auxiliary release with screwdriver

1.  Remove screw on the side of the safety switch 

(under the actuating slot).

2.  Using a small screwdriver, press the tongue 

inside in the direction of the LED until the 

actuator is released.

¨

¨

Guard locking is released.

Important!

 

f

The actuator must not be under tensile stress 

during manual release.

 

f

After use, reset the auxiliary release and tighten 

the locking screw with 0.3 to max. 0.5 Nm.

Auxiliary release with triangular key

Important!

 

f

Always turn triangular key to the respective stop.

 

f

If the key is not turned to the stop, incorrect 

switching or even damage to the safety switch 

may result.

Same function as for auxiliary release with screw-

driver.

Actuating auxiliary release

UNLOCK

LOCK

UNLOCK

LOCK

Figure 3:  Auxiliary release with triangular key

 

f

Insert triangular key in the release on the switch 

and turn 90° to the released position.

Important!

 

f

The actuator must not be under tensile stress 

during manual release.

Mounting

NOTICE

Device damage due to improper mounting and 

unsuitable ambient conditions.

 

f

Safety switches and actuators must not be used 

as an end stop.

 

f

Insert the actuator into the switch head prior to 

mounting.

 

f

Observe EN ISO 14119:2013, sections 5.2 and 

5.3, for information about fastening the safety 

switch and the actuator.

 

f

Observe EN  ISO  14119:2013, section 7, for 

information about reducing the possibilities for 

bypassing an interlocking device.

 

f

Protect the switch head against damage, as well 

as penetrating foreign objects such as swarf, 

sand and blasting shot, etc.

Electrical connection

 WARNING

Loss of the safety function due to incorrect 

connection.

 

f

Use only safe contacts   for safety functions. 

Monitoring contacts must not be used for safety 

functions.

 

f

When choosing the insulation material and 

wire for the connections, pay attention to the 

required temperature resistance and the max. 

mechanical load!

Use of the safety switch as guard locking for 

process protection

At least one contact   must be used (see Figure 

4 for terminal assignment).

Function test

 WARNING

Fatal injury due to faults during the function test.

 

f

Before carrying out the function test, make sure 

that there are no persons in the danger area.

 

f

Observe the valid accident prevention regula-

tions.

Check the device for correct function after installa-

tion and after every fault.
Proceed as follows:

Mechanical function test

The actuator must slide easily into the actuating 

head. Close the safety guard several times to check 

the function. The function of any manual releases 

(except for the auxiliary release) must also be tested.

Electrical function test

1.  Switch on operating voltage.
2.  Close all safety guards and activate guard 

locking.

¨

¨

The machine must not start automatically.

¨

¨

It must not be possible to open the safety guard.

3.  Start the machine function.

¨

¨

It must not be possible to release guard locking 

as long as the machine function is active.

4.  Stop the machine function and release guard 

locking.

¨

¨

The safety guard must remain locked until the 

process is no longer at risk.

¨

¨

It must not be possible to start the machine 

function as long as guard locking is released.

Repeat steps 2 - 4 for each safety guard.

Inspection and service

 WARNING

Danger of severe injuries due to the loss of the 

safety function.

 

f

If damage or wear is found, the complete switch 

and actuator assembly must be replaced. Re-

placement of individual parts or assemblies is 

not permitted.

 

f

Check the device for proper function at regular 

intervals and after every fault. For informa-

tion about possible time intervals, refer to 

EN ISO 14119:2013, section 8.2.

Inspection of the following is necessary to ensure 

trouble-free long-term operation:

 

f

correct switching function

 

f

secure mounting of all components

 

f

damage, heavy contamination, dirt and wear

 

f

sealing of cable entry

 

f

loose cable connections or plug connectors.

Information

: The year of manufacture can be seen 

in the bottom, right corner of the type label.

Exclusion of liability and warranty

In case of failure to comply with the conditions for 

correct use stated above, or if the safety instruc-

tions are not followed, or if any servicing is not 

performed as required, liability will be excluded and 

the warranty void.

EC declaration of conformity

The manufacturer named below herewith declares 

that the product fulfills the provisions of the direc-

tive(s) listed below and that the related standards 

have been applied.
EUCHNER GmbH + Co. KG 

Kohlhammerstr. 16 

D-70771 Leinfelden-Echterdingen
Directives applied:

 

f

Machinery directive 2006/42/EC

Standards applied:

 

f

EN 60947-5-1:2004 + Cor.:2005 + A1:2009

 

f

EN 1088:1995+A2:2008

 

f

EN 14119:2013

The original EC declaration of conformity can also 

be found at: www.euchner.de

Service

If service support is required, please contact:
EUCHNER GmbH + Co. KG

Kohlhammerstraße 16

D-70771 Leinfelden-Echterdingen

Service telephone

:

+49 711 7597-500

Fax

:

+49 711 753316

E-mail

:

[email protected]

Internet

:

www.euchner.de

Содержание TQ Series

Страница 1: ...n durch Personen oder brennbarem Material schützen Funktion Der Sicherheitsschalter ermöglicht das Zuhalten von beweglichen trennenden Schutzeinrichtungen für den Prozessschutz Im Schalterkopf befindet sich eine drehbare Schalt walze die durch den Zuhaltebolzen blockiert freigegeben wird Beim Einführen Herausziehen des Betätigers und beim Aktivieren Entsperren der Zuhaltung wird der Zuhaltebolzen ...

Страница 2: ...n vor Mechanische Funktionsprüfung Der Betätiger muss sich leicht in den Betätigungskopf einführen lassen Zur Prüfung Schutzeinrichtung mehr mals schließen Vorhandene manuelle Entriegelungen außer Hilfsentriegelung müssen ebenfalls auf deren Funktion geprüft werden Elektrische Funktionsprüfung 1 Betriebsspannung einschalten 2 Alle Schutzeinrichtungen schließen und Zuhal tung aktivieren Die Maschin...

Страница 3: ...h EN ISO 13849 1 B10d 2 x 106 SK ÜK A2 A1 WH BK A1 A2 SK ÜK A1 A2 SK ÜK Typ TQ1 0302G TQ2 0302G ÜK SK BN WH OG WH BU WH PK WH PK OG BN BU 12 22 32 11 21 31 42 52 41 51 41 51 42 52 11 21 31 12 22 32 BU BN OG PK PK WH BU WH OG WH BN WH SK ÜK Typ TQ1 1211G TQ2 1211G ÜK SK BN WH OG WH BU WH PK WH PK OG BN BU 12 22 34 11 21 33 42 54 41 53 ÜK SK BN WH OG WH BU WH PK WH PK OG BN BU 12 22 34 11 21 33 42 5...

Страница 4: ...Betaetiger Q GT 160 Betaetiger Q W 160 Radiusbetätiger Q LU 50 Radiusbetätiger Q RO 50 Bild 6 Minimale Türradien Radiusbetätiger Q LU 34 3 4 15 1 2 13 28 2 7 5 2 5 5 5 2 25 16 8 R2 1 2 0 2 0 Links Einstellschraube Einstellschraube Einstellschraube Unten für M4 Radiusbetätiger Q RO 2 0 34 3 4 15 1 2 13 28 2 7 5 2 0 2 5 5 5 2 25 16 8 R2 1 Rechts Einstellschraube Einstellschraube Oben für M4 ...

Страница 5: ...ION Danger due to high housing temperature f f Protect switch against touching by personnel or contact with inflammable material Function The safety switch permits the locking of movable safety guards for process protection In the switch head there is a rotating cam that is blocked released by the guard locking pin The guard locking pin is moved on the insertion removal of the actuator and on the ...

Страница 6: ...ter every fault Proceed as follows Mechanical function test The actuator must slide easily into the actuating head Close the safety guard several times to check the function The function of any manual releases except for the auxiliary release must also be tested Electrical function test 1 Switch on operating voltage 2 Close all safety guards and activate guard locking The machine must not start au...

Страница 7: ...lot duty Reliability values acc to EN ISO 13849 1 B10d 2 x 106 SK ÜK A2 A1 WH BK A1 A2 SK ÜK A1 A2 SK ÜK Typ TQ1 0302G TQ2 0302G ÜK SK BN WH OG WH BU WH PK WH PK OG BN BU 12 22 32 11 21 31 42 52 41 51 41 51 42 52 11 21 31 12 22 32 BU BN OG PK PK WH BU WH OG WH BN WH SK ÜK Typ TQ1 1211G TQ2 1211G ÜK SK BN WH OG WH BU WH PK WH PK OG BN BU 12 22 34 11 21 33 42 54 41 53 ÜK SK BN WH OG WH BU WH PK WH P...

Страница 8: ...structions Actuator Door radius min mm Actuator Q GT 160 Actuator Q W 160 Hinged actuator Q LU 50 Hinged actuator Q LU 50 Figure 6 Minimum door radii Hinged actuator Q LU 34 3 4 15 1 2 13 28 2 7 5 2 5 5 5 2 25 16 8 R2 1 2 0 2 0 Left Adjusting screw Adjusting screw Adjusting screw Bottom For M4 Hinged actuator Q RO 2 0 34 3 4 15 1 2 13 28 2 7 5 2 0 2 5 5 5 2 25 16 8 R2 1 Right Adjusting screw Adjus...

Страница 9: ... les protecteurs mobiles fermés et verrouillés en vue de la protection du process La tête de l interrupteur comporte un disque de commutation rotatif qui est bloqué libéré par le doigt de verrouillage L introduction retrait de la languette ou l activation déblocage du dispositif d interverrouillage provoque le déplacement du doigt Ceci a pour effet d actionner les contacts de commutation Lorsque l...

Страница 10: ...cidents Vérifiez le fonctionnement correct de l appareil à l is sue de l installation et après la survenue d un défaut Procédez de la manière suivante Contrôle du fonctionnement mécanique La languette doit rentrer facilement dans la tête d actionnement Pour le contrôle fermer plusieurs fois le protecteur Le fonctionnement des systèmes de déverrouillage manuel sauf le déverrouillage auxiliaire doiv...

Страница 11: ... surveillance Ui 150 V AC 15 1A 125VAC Pilot Duty DC 13 0 22A 125VDC Pilot Duty Valeurs de fiabilité selon EN ISO 13849 1 B10d 2 x 106 SK ÜK A2 A1 WH BK A1 A2 SK ÜK A1 A2 SK ÜK Typ TQ1 0302G TQ2 0302G ÜK SK BN WH OG WH BU WH PK WH PK OG BN BU 12 22 32 11 21 31 42 52 41 51 41 51 42 52 11 21 31 12 22 32 BU BN OG PK PK WH BU WH OG WH BN WH SK ÜK Typ TQ1 1211G TQ2 1211G ÜK SK BN WH OG WH BU WH PK WH P...

Страница 12: ...n mm Languette Q GT 160 Languette Q W 160 Languette articulée Q LU 50 Languette articulée Q RO 50 Figure 6 Rayons de porte minimum Languette articulée Q LU 34 3 4 15 1 2 13 28 2 7 5 2 5 5 5 2 25 16 8 R2 1 2 0 2 0 Liens Vis de réglage Vis de réglage Vis de réglage Bas pour M4 Languette articulée Q RO 2 0 34 3 4 15 1 2 13 28 2 7 5 2 0 2 5 5 5 2 25 16 8 R2 1 Droite Vis de réglage Vis de réglage Haut ...

Страница 13: ...sa di sicurezza consente di bloccare i ripari mobili di protezione per la protezione del processo Nella testina di azionamento si trova una camma rotante che viene bloccata sbloccata dal perno di chiusura Introducendo estraendo l azionatore e attivando sbloccando il meccanismo di ritenuta viene spostato il perno di chiusura Con questa operazione vengono azionati i contatti di commutazione Con la c...

Страница 14: ... Procedere come specificato di seguito Prova della funzione meccanica L azionatore deve potersi inserire facilmente nella testina di azionamento Effettuare questa prova chiudendo più volte il riparo di protezione Anche gli sblocchi manuali presenti escluso lo sblocco ausilia rio devono essere sottoposti alla prova funzionale Prova della funzione elettrica 1 Attivare la tensione di esercizio 2 Chiu...

Страница 15: ...ollo Ui 150 V AC 15 1 A 125 VAC Pilot Duty DC 13 0 22 A 125 VDC Pilot Duty Valori di affidabilità secondo EN ISO 13849 1 B10d 2 x 106 SK ÜK A2 A1 WH BK A1 A2 SK ÜK A1 A2 SK ÜK Typ TQ1 0302G TQ2 0302G ÜK SK BN WH OG WH BU WH PK WH PK OG BN BU 12 22 32 11 21 31 42 52 41 51 41 51 42 52 11 21 31 12 22 32 BU BN OG PK PK WH BU WH OG WH BN WH SK ÜK Typ TQ1 1211G TQ2 1211G ÜK SK BN WH OG WH BU WH PK WH PK...

Страница 16: ...paro min mm Azionatore Q GT 160 Azionatore Q W 160 Azionatore rotativo Q LU 50 Azionatore rotativo Q RO 50 Figura 6 Raggi del riparo minimi Azionatore rotativo Q LU 34 3 4 15 1 2 13 28 2 7 5 2 5 5 5 2 25 16 8 R2 1 2 0 2 0 Sinistra Vite di registro Vite di registro Vite di registro Sotto per M4 Azionatore rotativo Q RO 2 0 34 3 4 15 1 2 13 28 2 7 5 2 0 2 5 5 5 2 25 16 8 R2 1 Destra Vite di registro...

Страница 17: ... alta temperatura de la carcasa f f Proteja el interruptor para impedir que entre en contacto con personas o material inflamable Función El interruptor de seguridad permite bloquear resguar dos de seguridad móviles para proteger procesos En la cabeza del interruptor hay un disco de conmu tación giratorio que es bloqueado liberado por el perno de bloqueo Al introducir o extraer el actuador y al act...

Страница 18: ...el buen funcionamiento del dispositivo Proceda de la siguiente manera Comprobación mecánica del funcionamiento El actuador debe poder introducirse con facilidad en el cabezal actuador Para realizar la comprobación cierre varias veces el resguardo de seguridad También debe comprobarse el funcionamiento de los dispositivos de desbloqueo manuales salvo el desbloqueo auxiliar Comprobación eléctrica de...

Страница 19: ...ilot Duty CC 13 0 22 A 125 VCC Pilot Duty Valores de fiabilidad según EN ISO 13849 1 B10d 2 x 106 SK ÜK A2 A1 WH BK A1 A2 SK ÜK A1 A2 SK ÜK Typ TQ1 0302G TQ2 0302G ÜK SK BN WH OG WH BU WH PK WH PK OG BN BU 12 22 32 11 21 31 42 52 41 51 41 51 42 52 11 21 31 12 22 32 BU BN OG PK PK WH BU WH OG WH BN WH SK ÜK Typ TQ1 1211G TQ2 1211G ÜK SK BN WH OG WH BU WH PK WH PK OG BN BU 12 22 34 11 21 33 42 54 41...

Страница 20: ...ginal Actuador Radio de puerta mín mm Actuador Q GT 160 Actuador Q W 160 Actuador radial Q LU 50 Actuador radial Q RO 50 Figura 6 Radios de puerta mínimos Actuador radial Q LU 34 3 4 15 1 2 13 28 2 7 5 2 5 5 5 2 25 16 8 R2 1 2 0 2 0 Izquierda Tornillo de ajuste Tornillo de ajuste Tornillo de ajuste Parte inferior Para M4 Actuador radial Q RO 2 0 34 3 4 15 1 2 13 28 2 7 5 2 0 2 5 5 5 2 25 16 8 R2 1...

Отзывы: