23
2527247-01-09/19 (Translation of the original operating instructions)
Operating Instructions
Safety System MGBS-P-I-AP…
EN
5. System status table
Operating mode
Handle module/
door position
Safety outputs
FO1A and FO1B
Door monitoring
output OD
LED display
Output
State
ST
ATE (gr
een)
DIA (r
ed) and
diagnostic output OI
Normal operation
closed
on
on
Normal operation, door closed
open
off
off
1 x
Normal operation, door open
Teach-in operation
(only unicode)
open
off
off
3 x
Device in teach-in standby
closed
off
on
1 Hz
Teach-in operation
X
off
X
Positive acknowledgment after completion of teach-in operation
Fault display
X
off
X
1 x
Fault in the teach-in operation (only unicode)
Handle module removed from the operating distance prior to the end of the teach-in opera-
tion or faulty handle module detected.
X
off
off
2 x
Input fault
Test pulses on the safety outputs cannot be read due to synchronous tests pulses on UB.
X
off
off
3 x
Read error
(e.g. handle module faulty)
X
off
off
4 x
Output error
(e.g. short circuits, loss of switching ability)
X
off
X
5 x
Disabled handle module detected
X
off
off
Internal error
Key to symbols
LED not illuminated
LED illuminated
10 Hz (8 s)
LED flashes for 8 s at 10 Hz
3 x
LED flashes three times, and this is then repeated
LEDs flash alternately
X
Any state
After the cause has been remedied, faults can generally be reset by opening and closing the guard. If the fault is still dis-
played afterward, use the reset function or briefly interrupt the power supply. Please contact the manufacturer if the fault
could not be reset after restarting.
Important!
If you do not find the displayed device status in the system status table, this indicates an internal device
fault. In this case, you should contact the manufacturer.