Manual EKS Electronic-Key Adapter USB
Page 32/34
Subject to technical modifications
2094485-05-07/19
8.5 Command overview
Description
Command message
Reply message
Program Electronic-Key
TP
(see chapter 8.4.1)
RF
(see chapter 8.4.1)
Read Electronic-Key
(also read the serial number)
TL
RL
(see chapter 8.4.2)
or
RF
(see chapter 8.4.2)
8.6 Status numbers
Value
Description
00
hex
No error
02
hex
Electronic-Key not in the operating distance
03
hex
Parity bit error on read-only Electronic-Key
06
hex
Write process interrupted. Start address or number of bytes is not a multiple of the block size 4
17
hex
Read attempt when the Electronic-Key adapter is set to Electronic-Key read/write and a read-only
Electronic-Key is inserted
18
hex
Read attempt when the Electronic-Key adapter is set to read-only Electronic-Key and an Electronic-Key
read/write is inserted
4x
hex
General Electronic-Key communication error (renewed write or read process necessary)
50
hex
Write attempt despite enabled write protection