23
2136918-04-05/19 (translation of the original operating instructions)
Operating Instructions
Transponder-Coded Safety Switch CTP-LBI-AP
EN
13. Technical data
NOTICE
If a data sheet is included with the product, the information on the data sheet applies.
13.1. Technical data for safety switch CTP-LBI-AP
Parameter
Value
Unit
min.
typ.
max.
General
Material
- Switch head
- Switch housing
Die-cast zinc
Reinforced thermoplastic
Installation position
Any
Degree of protection
1)
with plug connector M12
IP 67/IP 69/IP 69K
with plug connector M23
IP 67
(screwed tight with the related mating connector)
Safety class according to EN IEC 61558
III
Degree of contamination
3
Mechanical life
1 x 10
6
operating cycles
Ambient temperature at UB = 24 V
-20
-
+55
°C
Actuator approach speed, max.
20
m/min
Actuating/extraction/retention force at 20 °C
8/10/5
N
Locking force F
max
2)
3900
N
Locking force F
Zh
2)
according to EN ISO 14119
F
Zh
= F
max
/1.3 = 3,000
N
Weight
Approx. 0.42
kg
Connection type (depending on version)
2 plug connectors M12, 5- and 8-pin
1 plug connector RC18, 19-pin (as yet no UL approval)
1 plug connector M12, 8-pin
Operating voltage UB (reverse polarity protected, regulated,
residual ripple < 5 %)
24 ± 15% (PELV)
V DC
Current consumption I
UB
40 mA at IMP = 24 V, 440 mA at IMP = 0 V
mA
For the approval according to UL the following applies
Operation only with UL class 2 power supply, or equivalent measures
Switching load according to UL
DC 24 V, class 2
External fuse (operating voltage UB)
3)
0.25
-
8
A
External fuse (solenoid operating voltage IMP)
3)
0.5
-
8
A
Rated insulation voltage U
i
-
-
50
V
Rated impulse withstand voltage U
imp
-
-
0.5
kV
Rated conditional short-circuit current
100
A
Resilience to vibration
Acc. to EN 60947-5-3
EMC protection requirements
Acc. to EN 60947-5-3
Ready delay
-
-
1
s
Risk time
-
-
260
ms
Switch-on time
-
-
400
ms
Discrepancy time
-
-
10
ms
Test-pulse duration
0.35
ms
Frequency band
120 … 130
kHz
Safety outputs FO1A/FO1B
Semiconductor outputs, p-switching, short circuit-proof
- Output voltage U
FO1A
/U
FO1B
4)
V DC
HIGH U
FO1A
/U
FO1B
UB - 1.5
-
UB
LOW U
FO1A
/U
FO1B
0
-
1
Switching current per safety output
1
-
150
mA
Utilization category acc. to EN 60947-5-2
DC-13 24 V 150 mA
Caution: outputs must be protected with a free-wheeling diode in case of inductive loads
Switching frequency
5)
0.5
Hz
Monitoring outputs OL, OI, OD
p-switching, short circuit-proof
Output voltage
0.8 x UB
-
UB
V DC
Max. load
-
-
50
mA
Solenoid
Solenoid operating voltage IMP
(reverse polarity protected, regulated, residual ripple
< 5 %)
HIGH
15 … 24
V DC
LOW
0 … 5
Solenoid current consumption I
IMP
20
mA
Power consumption
1.7
W
Duty cycle
100
%
Reliability values acc. to EN ISO 13849-1
Guard locking monitoring
Control of guard locking
Category
4
B
Performance Level (PL)
e
b
PFH
D
4.1 x 10
-9
/h
2.1 x 10
-9
/h
Mission time
20
20
years
1) In order to achieve the specified degree of protection, the rear side of the switch must be covered but must not be sealed.
2) Dependent on the actuator used.
3) Trip characteristic medium slow-blow.
4) Values at a switching current of 50 mA without taking into account the cable lengths.
5) Corresponds to the actuation frequency.