Operating Instructions
Transponder-Coded Safety Switch CTP-LBI-AP
12
(translation of the original operating instructions) 2136918-04-05/19
7.3.
Escape release (optional)
Permits opening of a locked guard from the danger zone without tools (see chapter
drawing for safety switch CTP… on page 26
).
Important!
Ì
It must be possible to actuate the escape release manually from in-
side the protected area without tools.
Ì
It must not be possible to reach the escape release from the outside.
Ì
The actuator must not be under tensile stress during manual release.
Ì
The escape release meets the requirements of Category B according
to EN ISO 13849-1:2015.
7.3.1. Actuating escape release
Ì
Press the red release knob to the end stop
¨
Guard locking is released.
Pull the knob out again to reset.
The safety outputs are switched off when the escape release is actuated. Use the safety outputs
to generate a stop
command.
The monitoring output OL is switched off; OD can assume an undefined state. Open the guard and close it again after re-
setting the escape release. The device will then operate normally again.
After manual unlocking, the solenoid must be energized briefly to re-establish the defined state.