10.3. Functional check
WARNING
Danger of fatal injury as a result of faults in installation and functional check.
Ì
Before carrying out the functional check, make sure that there are no persons in the danger zone.
Ì
Observe the valid accident prevention regulations.
10.3.1. Mechanical function test
The actuator must slide easily into the switch. Close the guard several times to check the function.
10.3.2. Electrical function test
After installation and any fault, the safety function must be fully checked. Proceed as follows:
With active guard lock monitoring:
1. Switch on operating voltage.
¨
The machine must not start automatically.
¨
The safety switch carries out a self-test. The green STATE LED then flashes at regular intervals.
2. Close all guards. In case of guard locking by solenoid force: activate guard locking.
¨
The machine must not start automatically. It must not be possible to open the guard.
¨
The green STATE LED and the yellow LOCK LED are illuminated continuously.
3. Enable operation in the control system.
¨
It must not be possible to deactivate guard locking as long as operation is enabled.
4. Disable operation in the control system and deactivate guard locking.
¨
The guard must remain locked until there is no longer any risk of injury.
¨
It must not be possible to start the machine as long as the guard locking is deactivated.
Repeat steps 2 - 4 for each guard.
With inactive guard lock monitoring:
With inactive guard lock monitoring
1. Switch on operating voltage.
¨
The machine must not start automatically.
The safety switch carries out a self-test. The green STATE LED then flashes at regular intervals
.
2. Close all guards. As soon as the actuator is inserted into the switch, the safety outputs FO1A/FO1B are ON.
Independent of whether the guard locking is active or not.
¨
The machine must not start automatically. It must not be possible to open the guard.
¨
The green State LED illuminates continuously. The yellow Lock LED is ON for a long time with a short interruption or
permanently ON (depending on the guard locking state)
3. Enable operation in the control system.
4. If necessary, deactivate guard locking and open guard.
¨
The machine must switch off and it must not be possible to start it as long as the guard is open.
Repeat steps 2-4 for each guard.
10.4. Factory reset
Connect the two outputs FO1A and FO1B to 0 V or set the bit
0x1E
via the BR chain.