background image

3

Safety Information and Maintanance

(Part of the Operating Instructions for Safety Switch CET/CTP (AS))

Scope

This safety information is part of the operating 

instructions for safety switch CET or CTP of the 

output families -AS.

Correct use

The aforementioned safety switches are operated 

as slaves on the safety bus AS-Interface Safety at 

Work and function as interlocking devices with guard 

locking (type  4). Devices with unicode evaluation 

possess a high coding level, devices with multicode 

evaluation possess a low coding level.
For guard locking for personnel protection the 

following applies: 
In combination with a movable safety guard and the 

machine control, this safety component prevents the 

safety guard from being opened while a dangerous 

machine function is being performed.
This means:

 

f

Starting commands that cause a dangerous ma-

chine function must become active only when the 

safety guard is closed and locked.

 

f

The guard locking device must not be unlocked 

until the dangerous machine function has ended.

 

f

Closing and locking a safety guard must not cause 

automatic starting of a dangerous machine func-

tion. A separate start command must be issued. 

For exceptions, refer to EN ISO 12100 or relevant 

C-standards.

For guard locking for process protection the 

following applies: 
In combination with a movable safety guard and 

the machine control, this safety component pre-

vents dangerous machine functions from occurring 

while the safety guard is open. A stop command is 

triggered if the safety guard is opened during the 

dangerous machine function. With inactive guard 

lock monitoring, guard locking must be used only 

for process protection.
This means:

 

f

Starting commands that cause a dangerous ma-

chine function must become active only when the 

safety guard is closed.

 

f

Opening the safety guard triggers a stop com-

mand.

 

f

Closing a safety guard must not cause automatic 

starting of a dangerous machine function. A 

separate start command must be issued. For 

exceptions, refer to EN  ISO  12100 or relevant 

C-standards.

Before the device is used, a risk assessment must 

be performed on the machine, e.g. in accordance 

with the following standards:

 

f

EN ISO 13849-1, Safety of machinery – Safety-re-

lated parts of control systems – Part 1: General 

principles for design

 

f

EN  ISO  12100, Safety of machinery – Basic 

concepts – General principles for design – Risk 

assessment and risk reduction

 

f

IEC  62061, Safety of machinery – Functional 

safety of safety-related electrical, electronic and 

programmable electronic control systems

Correct use includes observing the relevant require-

ments for installation and operation, particularly 

based on the following standards:

 

f

EN ISO 13849-1, Safety of machinery – Safety-re-

lated parts of control systems – Part 1: General 

principles for design 

 

f

EN ISO 14119 (supersedes EN 1088), Safety of 

machinery – Interlocking devices associated with 

guards – Principles for design and selection

 

f

EN  60204-1, Safety of machinery – Electrical 

equipment of machines – Part 1: General re-

quirements

The safety switch must be used only in conjunction 

with the designated actuator from EUCHNER. On 

the use of different actuators, EUCHNER provides 

no warranty for safe function.

Important!

 

f

Correct use requires observing the permissible 

operating parameters (see Technical data).

 

f

The user is responsible for the proper integration 

of the device into a safe overall system. For this 

purpose, the overall system must be validated, 

e.g. in accordance with EN ISO 13849-2.

Exclusion of liability and warranty

In case of failure to comply with the conditions for 

correct use stated above, or if the safety instruc-

tions are not followed, or if any servicing is not 

performed as required, liability will be excluded and 

the warranty void.

General safety instructions

Safety switches fulfill personal protection functions. 

Incorrect installation or tampering can lead to fatal 

injuries to personnel.
Check the safe function of the safety guard par-

ticularly

 

f

after any setup work

 

f

after the replacement of a system component

 

f

after an extended period without use

 

f

after every fault

Independent of these checks, the safe function of the 

safety guard should be checked at suitable intervals 

as part of the maintenance schedule.

 WARNING

Danger to life due to improper installation or due 

to bypassing (tampering). Safety components 

perform a personal protection function.

 

f

Safety components must not be bypassed, 

turned away, removed or otherwise rendered 

ineffective. On this topic pay attention in partic-

ular to the measures for reducing the possibility 

of bypassing according to EN ISO 14119:2013, 

section 7.

 

f

The switching operation must be triggered only 

by actuators designated for this purpose.

 

f

Prevent bypassing by means of replacement 

actuators (only for multicode evaluation). For this 

purpose, restrict access to actuators and to keys 

for releases, for example.

 

f

Mounting, electrical connection and setup only 

by authorized personnel possessing the following 

knowledge:

 - specialist knowledge in handling safety com-

ponents 

 - knowledge about the applicable EMC regu-

lations

 - knowledge about the applicable regulations on 

occupational safety and accident prevention.

Important!
Prior to use, read the operating instructions and 

keep these in a safe place. Ensure the operating 

instructions are always available during mounting, 

setup and servicing. EUCHNER cannot provide any 

warranty in relation to the readability of the CD for 

the storage period required. 
For this reason you should archive a printed copy 

of the operating instructions. You can download 

the operating instructions from www.euchner.de.

Operating instructions on CD/DVD

Each device is supplied with operating instructions 

on CD/DVD, which contain detailed information on 

the overall system. The following system require-

ments must be met to be able to display or print 

the document:

 

f

PC with PDF reader installed

 

f

CD/DVD drive

Opening and printing the documents
Important: The autoplay function for the drive must 

be enabled (see operating system help), and you 

will need an up-to-date PDF reader.
1.  Insert CD/DVD

¨

¨

Selection table is opened in the browser

2.  Click the related document for your system

¨

¨

The document is opened and can be printed.

Mounting, setup and 

troubleshooting

For detailed instructions on mounting, setup and 

troubleshooting, please refer to the operating 

instructions on the CD/DVD.

 CAUTION

Safety switches must not be bypassed (bridging 

of contacts), turned away, removed or otherwise 

rendered ineffective.

 

f

Observe EN  ISO  14119:2013, section 7, for 

information about reducing the possibilities for 

bypassing an interlocking device.

 

f

The following applies to CET: The safety switch 

must be mounted with the ramp facing down 

or horizontal in order to achieve category 4 in 

accordance with EN 13849-1 for safety guard 

position monitoring.

NOTICE

Risk of damage to equipment and malfunctions as 

a result of incorrect installation.

 

f

Safety switches and actuators must not be used 

as an end stop.

 

f

Observe EN ISO 14119:2013, sections 5.2 and 

5.3, for information about fastening the safety 

switch and the actuator.

 

f

Protect the switch head against damage, as well 

as penetrating foreign objects such as swarf, 

sand and blasting shot, etc.

 

f

Observe the min. door radii (see associated 

operating instructions).

Electrical connection

For detailed information on the electrical connec-

tion, please refer to the operating instructions on 

the CD/DVD.

1

  AS-Int

2

  Auxiliary voltage 0 V

3

  AS-Interface -

4

  Auxiliary voltage 24 V

View of plug connector

Safety switch

4

3

1

2

Содержание CET Series

Страница 1: ...rleistung Wenn die o g Bedingungen für den bestimmungsge mäßen Gebrauch nicht eingehalten werden oder wenn die Sicherheitshinweise nicht befolgt werden oder wenn etwaige Wartungsarbeiten nicht wie gefordert durchgeführt werden führt dies zu einem Haftungs ausschluss und dem Verlust der Gewährleistung Allgemeine Sicherheitshinweise Sicherheitsschalter erfüllen Personenschutz Funktio nen Unsachgemäß...

Страница 2: ...lussart Steckverbinder M12 4 polig Risikozeit Einzelgerät 400 ms Magnet Hilfsspannung DC 24 V 10 15 PELV Stromaufnahme Hilfsspannung 400 mA Einschaltdauer ED 100 AS Interface Daten EA Code 7 ID Code B Gesamtstromaufnahme max 30 mA Gültige AS Interface Adressen 1 31 AS Interface Eingänge nach ASi Safety at Work Türüberwachungskontakt D0 D1 Magnetüberwachungskontakt D2 D3 AS Interface Ausgänge Zuhal...

Страница 3: ...med as required liability will be excluded and the warranty void General safety instructions Safety switches fulfill personal protection functions Incorrect installation or tampering can lead to fatal injuries to personnel Check the safe function of the safety guard par ticularly f f after any setup work f f after the replacement of a system component f f after an extended period without use f f a...

Страница 4: ...y voltage 400 mA Duty cycle 100 AS Interface data EA code 7 ID code B Total current consumption Max 30 mA Valid AS Interface addresses 1 31 AS Interface inputs Acc to ASi Safety at Work Door monitoring contact D0 D1 Solenoid monitoring contact D2 D3 AS Interface outputs Guard locking solenoid D0 1 solenoid energized Red LED D1 1 LED on Green LED D2 1 LED on Reliability values acc to EN ISO 13849 1...

Отзывы: