Operating Instructions
Non-Contact Safety System CES-A-ABA-01/CES-A-ABA-01B
10
(translation of the original operating instructions) 071873-15-07/15
7. Mounting
NOTICE
Device damage due to improper installation or unsuitable ambient conditions.
Ì
Read heads and actuators must not be used as a mechanical end stop.
Ì
Observe EN ISO 14119:2013, sections 5.2 and 5.3, for information about fastening the safety
switch and the actuator.
Ì
Observe EN ISO 14119:2013, section 7, for information about reducing the possibilities for by-
passing an interlocking device.
Ì
The evaluation unit must be mounted in a control cabinet with a minimum degree of protection of
IP54. A snap-in element on the rear of the device is used for fastening to a mounting rail.
Ì
If several evaluation units are mounted side by side in a control cabinet without air circulation
(e.g. fan), a minimum distance of 10 mm must be maintained between the evaluation units. This
distance enables the heat from the evaluation unit to dissipate.
Important!
Ì
From the assured switch-off distance S
ar
, the safety outputs are safely shut down.
Ì
When mounting several read heads, observe the stipulated minimum distance to avoid mutual in-
terference.
-For CES-A-LNA/-LCA s
min
= 50 mm
-For CES-A-LMN
s
min
= 20 mm
-For CES-A-LQA
s
min
= 80 mm
s
min
Ì
If the actuator is installed flush, the switching distance changes as a function of the installation
depth and the safety guard material.
Operating
distance
Actuator
Operating
distance
Actuator
Flush mounting
Surface mounting
Note the following points:
Ì
Actuator and read head must be fitted so that
-the front faces are at the minimum switch-on distance 0.8 x S
ao
or closer when the safety guard is closed (see section
Operating distances). To avoid entering the area of possible side lobes, a minimum distance is to be maintained in
case of a side approach direction. See section Typical operating distance for the related actuator.
-a hazard is excluded until the assured switch-off distance (S
ar
) is reached when the safety guard is open.
-the actuator is positively mounted on the safety guard, e.g. by using the safety screws included.
-they cannot be removed or tampered with using simple means.
Ì
Pay attention to the maximum tightening torque for the read head or safety switch and actuator mountings of 1 Nm. For
read heads/actuators made of PE-HD, the maximum tightening torque is only 0.5 Nm.