14.4. Acknowledging error messages
If the DIA LED flashes inversely once, the error message can be acknowledged by opening and closing the guard. If the
error is still displayed afterward, a reset must be performed.
If the LED DIA is permanently illuminated, the error message can be acknowledged only by a reset.
The reset can be performed as follows.
Reset
Centrally for all
switches of a
chain
Each switch
must be
addressed
separately
Further information
By briefly disconnecting the power supply
-
-
Via the cyclical data of IO-Link communication
-
See operating instructions for the IO-Link Gateway
Via the acyclical data of IO-Link communication
-
11.3.2. Acyclical data (device data and events) on page
Resetting to acknowledge error messages does not delete the parametrization.
Important!
Contact the manufacturer if the fault display is not reset after briefly disconnecting the power supply.