Operating Instructions Safety Systems
MGB-L..B-PN.-… (PROFINET) and With Data Structure Type A
34
(translation of the original operating instructions) 2114575-06-02/21
18. Technical data
NOTICE
If a data sheet is included with the product, the information on the data sheet applies.
Parameter
Value
s
ar
max. door position
65 mm
Housing material
Fiber glass reinforced plastic
Die-cast zinc, nickel-plated,
stainless steel,
powder-coated sheet steel
Dimensions
See dimension drawing
Weight of MGB-L.B (bus module, locking module and operating module with mount-
ing plate)
4.05 kg
Weight of handle module with mounting plate
1.20 kg
Weight of escape release module with mounting plate
1.15 kg
Ambient temperature
-20 … +55 °C
Degree of protection
IP54
Safety class
III
Degree of contamination
3
Installation orientation
Any
Locking force F
zh
acc. to GS-ET-19
2,000 N
Connection options, power supply
2 x push-pull power
1)
or 2 x plug connectors 7/8" acc. to ANSI/B93.55M-1981
Connection, bus
2 x RJ 45, push-pull, acc. to IEC 61076-3 117, variant 14, screened
1)
or 2 x M12 (d-coded) acc. to IEC 61076-2-101
Connecting cable, bus
Profinet I/O cable, at least cat. 5e
Operating voltage U
B
DC 24 V +10% / -15%
(PELV – see chapter
13. Electrical connection on page 25
)
Current consumption, max.
500 mA
Max. feed-in current in the connection block (push-pull plug connector)
4,000 mA
Fuse protection for power supply, external
Min. 1 A slow-blow
Safety outputs
Profisafe acc. to IEC 61784-3-3
Rated insulation voltage U
i
75 V
Rated impulse withstand voltage U
imp
0.5 kV
Resilience to vibration and shock
Acc. to EN 60947-5-3
EMC protection requirements
Acc. to EN 61000-4
and DIN EN 61326-3-1
Switching frequency, max.
1 Hz
Risk times, max. (turn-off times)
2)
- Emergency stop
- Enabling switch
- Operating mode selector
- Door position
- Bolt position
- Guard locking
250 ms
250 ms
220 ms
550 ms
550 ms
550 ms
Reliability values acc. to EN ISO 13849-1
Category
4 (EN 13849-1:2008-12)
Performance Level
PL e (EN 13849-1:2008-12)
MTTF
D
3)
91 years
DC
99%
Mission time
20 years
PFH
D
3)
- Monitoring of guard locking
- Control of guard locking
- Evaluation of emergency stop, enabling switch, multi-position switch
4.07 x 10
-8
3.91 x 10
-8
4.10 x 10
-8
B
10D
4)
- Emergency stop
- Enabling switch
0.13 x 10
6
Acc. to manufacturer’s specifications
1) The document
PROFINET Cabling and Interconnection Technology
from the PNO aids in the correct selection of cables.
2) The risk time is the max. time between the change in the input status and the clearing of the corresponding bit in the bus protocol.
3) Fixed failure rate without consideration of faults in wearing parts.
4) Information regarding wearing parts without consideration of fixed failure rates in electronic components.