27971-01A
37
Problem
Solution
Sunbed not tanning
Lamps fail to light and timer dis-
play is blank
One or more lamps fail to light
The face tanners will not
come on
The canopy will not stay up /
The canopy will not stay down
My canopy opens and closes too
fast (slamming, not enough resis-
tance)
Timer display is indicating E 91
Timer display is indicating E 92
Timer display is indicating E 93
1. Clean sunbed, see
Thorough Periodic Cleaning
.
2. Ensure supply voltage is between 208 and 230V AC.
3. Replace lamps if lamp hours are greater than 500hrs.
4. Replace acrylic.
1. Make sure the unit is connected to a power source.
2. Check source of AC power. Reset circuit breaker or replace fuse.
1. Check that lamp is installed correctly.
2. Switch unlit lamp with a lamp that lights, if new lamp lights
and old lamp still does not, replace old lamp.
1. Face tanner operation is initially delayed by 5 seconds.
2. Face tanners will not relight for 1 minute if turned off.
3. Replace face tanner lamp, see
Removing/Replacing Face
Tanner Lamps
.
Your sunbed uses a smooth gliding spring lift system to raise
the canopy. This lift system may need to be adjusted slightly
from time to time. See
Under the Bench
for proper adjustment
procedures. The canopy should raise easily as well as rest fully
closed.
Your sunbed utilizes a damper which limits the canopy’s
movement speed. This also serves as a safety device in case of
spring lift failure as the canopy will not crash down. The
damper looks like a gas spring attached to the left hinge arm.
Replace if necessary.
Timer software error. Disconnect and reapply power to the unit.
Current sensor indicating unit is off when it should be on.
Contact servicer.
Current sensor indicating unit is on when it should be off.
Contact servicer.
roubleshooting
Содержание solarforce 648
Страница 1: ...27971 01A...
Страница 45: ...27971 01A 40 Notes...
Страница 46: ...27971 01A 41 Notes...