40
OPERA
TION
Operation
Burner Control
To control the burners, tap Burner Control to show a pop-up. Desired product temperature can be adjusted up
or down. This always begins at 95 F when the controls are turned on. The Upper burner and Lower burner can
be turned ON or OFF. A flame icon will be visible on the left side of Burner Control while the Lower burner is ON,
and the right side of Burner Control while the Upper burner is ON. While either burner is ON, the flame icon will
be visible in the header.
A timer is shown in Burner Control that begins counting down when a single burner is turned on, and will shut
both burners OFF when finished. The timer begins at 60 minutes, or 15 minutes if there is poor feedback from
the temperature sensor. While less than five minutes remain on the timer, all flame icons will flash as a reminder
the burners will be shutting off soon. To reset the timer and extend burn time, hold the red Reset Timer button
for 5 seconds.
Burners can only operate in the operation modes Suck Back, Load, Tank Circ, or Bar Circ. These are the top
four modes shown in the Operation Mode pop-up on the touchscreen. The control will be hidden if not in one
of those modes. Refer to the Ignition and Out Fire Control section on the next page for complete instructions of
operating the burners.
Figure 50 - Burner Control
Lower
Burner
Icon
At least one
burner is on
Upper
Burner
Icon