EN 19
INSTALLATION
Electrical connection
This appliance is set as standard for 2 phase with 1 zero connection,
but can also be connected to 1 phase.
2 phases with 1 zero connection (2 1N, 380 V ~ / 50 Hz):
• Fit connection bridges between the connecting points 4 and 5.
The voltage between the phases and the zero is 230 V and the voltage
between the phases is 400 V. The fuse box in your home must be fitted
with a 16 Amp (2x) fuse. The connection cable must be minimally 2.5 mm
2
in diameter.
2 phase and 2 zero connection (2 2N, 230 V ~ / 50 Hz)
The voltage between the phases and the zeros is 230 V~ and the
voltage between phases is 0 V. The group must have fuses of at least
16 A (2x). The connection cable must be minimally 2.5 mm
2
in diameter.
1 phase with 1 zero connection (1 1N, 230 V ~ / 50 Hz):
• Fit connection bridges between the connecting points 4 and 5
and 1 and 2. Power limiter needs to be set to “Lo” (for 1x16 Amp
connection).
Comment:
connection 3 will not be used
Ø 4 x 2,5mm
2 x 16
A
2
Ø 5 x 2,5mm
2 x 16
A
2
Ø 3 x 2,5mm
1 x 16
A
(Lo)
Ø 3 x 6 mm
1 x 32
A
(Hi)
2
2