background image

Use as a standalone alarm system  

Before using the ES-S6A as a standalone alarm system, it must be connected to 

a remote control or an accessory (e.g. motion detector, door / window contact).

When the system is armed, if a sensor is triggered, the siren will ring out and the 

LED lights will turn on.

Connect a remote control

Press the Connect button on the siren. The siren beeps once and the LEDs light up: 

the siren is now in Connection Mode.

Press any button on the remote control.

You hear one beep: the remote control has been connected to the siren successfully 

(if you hear 3 beeps, the remote control has already been connected).

Connect a wireless sensor

Press the Connect button on the siren. The siren beeps once and the LEDs light up: 

the siren is now in Connection Mode.

Trigger the sensor (e.g. walk in front of the sensor if you want to connect a motion 

detector)

You hear one beep: the accessory has been connected to the siren successfully (if 

you hear 3 beeps, the accessory has already been connected).

The siren supports up to 10 remote controls and 10 wireless detectors.

Содержание ES-S6A

Страница 1: ...www etiger com ES S6A Indoor Siren EN Instrukcja pobrana ze sklepu www ekocentrum24 pl ...

Страница 2: ... wireless detectors Wireless connection for an easy installation Radio frequency security of the accessories more than one million of codes combinations Simplified connection to accessories Can be connected to all of eTiger Secual accessories Built in 4 2V 600 mAh lithium batteries 8 hour battery life in standby mode Box Content 1 x ES S6A 1 x User Manual ...

Страница 3: ... plug Several ES S6A can be installed throughout your home and connected to your alarm system When the alarm of your system is triggered the ES S6A rings out and its LEDs switch on The ES S6A can also be used as a standalone siren and can be connected to wireless sensors and or to a remote control ...

Страница 4: ...Setup Mode Power off Enter Setup Mode by pressing the Power button once Press again the Power button for 6 secondstoturnthesirenoff Siren and light indications When arming the system The siren beeps once the LED lights blink once and switch on When disarming the system The siren beeps twice the LED lights blink twice and turn off When armed disarmed in Mute Mode from the control panel The siren do...

Страница 5: ...the SOS or Arm button on the control panel of your alarm system You hear one beep the siren has been registered in the control panel successfully if you hear 3 beeps the siren has already been connected Press the Connect button again on the siren to exit the Connection Mode Note Do not trigger an alarm with a sensor when registering the siren in the control panel Test Press the Arm button on the c...

Страница 6: ...e Press any button on the remote control You hear one beep the remote control has been connected to the siren successfully if you hear 3 beeps the remote control has already been connected Connect a wireless sensor Press the Connect button on the siren The siren beeps once and the LEDs light up the siren is now in Connection Mode Trigger the sensor e g walk in front of the sensor if you want to co...

Страница 7: ...n to a wireless sensor Arm the system Trigger the sensor e g walk in front of the sensor if you have connected a motion detector The siren rings out the connection of the sensor is successful If not the connection has failed try registering the sensor again Clear all accessories Press the Connect button on the siren for 6 seconds until you hear two beeps The LEDs blink twice all the accessories an...

Страница 8: ... alarm the ringing out of the siren will be delayed accordingly The name of the Delay Zone and the connection process may vary depending on models Refer to the user manual of your alarm system for more information Set up the delay Enter Setup Mode by pressing the power button once Press the power button again once to set the delay to 10 seconds twice to set the delay to 20 seconds three times to s...

Страница 9: ...manual of your alarm system Night Lamp mode When used as a standalone alarm system the ES S6A can also be used as an LED night lamp Press the Home Mode button on the remote control twice the siren switches to Home Mode and the strobe light turns into a night lamp Press the Home Mode button twice then the Arm button once the siren is in monitoring mode with night lamp on Press the Disarm button the...

Страница 10: ...e 90dB Backup battery 4 2V 600mA Lithium Static current 13mA Alarm current 300mA Radio frequency 433MHz 75KHz Housing material ABS plastic Operating conditions Temperature 10 C 55 C Relative Humidity 80 non condensing Dimensions 81 x 80 x 76 mm ...

Страница 11: ...y dangerous for the environment and human health due to the presence of hazardous substances In compliance with European laws This product is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC R TTE This product was designed and manufactured in compliance with Directive 2002 95 EC of the European Parliament and of the Council on the restriction of us...

Страница 12: ...Images illustrations and text are non contractual ETIGER and the ETIGER logo are registered trademarks and the property of ETIGER Copyright 2014 ETIGER All rights reserved ES S6A UM EN20150223 2 0 W ...

Страница 13: ...This user manual is available in other languages at www etiger com eu support ETIGER EUROPE Rue de la Loi 25 7100 La Louvière Belgium service etiger com ...