5 www.ETiSSL.com
Please contact 1-855-384-7754 for further assistance.
Installation (continued)
3
Feeding the wires
NOTE:
Put the gasket (BB) on any knock out hole on the fixture to better protect the wires.
□
Feed the electrical connection wires through any knock out hole, through the gasket (BB), and then through
the mounting bracket (AA). The connection wires can be held in place by the metal tabs on the wrap light
housing (A), if needed.
4
Making the electrical connections
□
Insert the hot and neutral (black and white) wires from the electrical box into the wire connectors of
the same color wires from the housing (A).
□
Insert the ground wire from the electrical box into the wire connector attached to the green wire from
the housing (A).
□
If a 0-10v dimming circuit is available, connect the purple and gray wires from the fixture housing (A)
to the same color wires in the electrical box.
□
Cover the wire connections using the wire connectors (not included).
□
If 0-10v dimming is not desired, wrap the ends of the purple and gray wires with electrical tape to
cover the wire.
□
Wrap the wire connectors with electrical tape for a more secure connection.
AA
BB
Metal tabs
Knock out holes
A
Wire
connectors
AA
A
Wire
connectors