AC POWER SUPPLY MODULE REPLACEMENT PROCEDURE  |  PART NO. 

24732 

REV 

B.0

5

MODEL ADH NEMA

AC POWER SUPPLY MODULE

REPLACEMENT PROCEDURE

AC Power Supply Module  Terminals 

1

2

3

4

5

6

7

Wire Color 

Black 

White 

Green / Yellow

Not used 

Black 

Red 

Not used 

Wire Function 

Neutral 

Line 

Ground 

– 

Ground 

(Return) 

+24V

(Positive) 

– 

Table 1. -  AC POWER SUPPLY MODULE ELECTRICAL CONNECTIONS.