Figure 1.A - DISCONNECTING THE ETHERNET CABLE,
THE POWER CABLE CONNECTOR, AND THE GROUND WIRE.
Figure 2. - THE AC POWER SUPPLY MODULE MOUNTING BRACKET.
Figure 1.B - DISCONNECTING THE ETHERNET CABLE,
THE POWER CABLE CONNECTOR, AND THE GROUND WIRE.
AC POWER SUPPLY MODULE REPLACEMENT PROCEDURE | PART NO.
24732
REV
B.0
3
Shut off machine power by unplugging the unit.
Open the two front door latches, loosen the two captive
screws in the corners of the housing opposite the
hinges, then open the NEMA box. Place an object
underneath the door once open to help support it
during this procedure.
Remove the orange ethernet cable on the left by
disconnecting both ends, then removing it. Set aside for
re-use. Remove the power cable connector on the right
by loosening the captive screw on each end of the green
connector, then unplugging the connector. Disconnect
the ground wire by loosening the ground wire retaining
screw, then carefully removing the ground wire. Refer to
Figures 1.A & 1.B.
Remove and retain the four mounting screws from the
four corners of the protective front cover, then slowly lift
the front cover, carefully flip it over, then set it down,
upside down, to rest on the inside of the enclosure door.
Be careful as there are still many wires connected
between the enclosure and the front cover and there
isn’t a lot of slack. Note that the two upper front cover
mounting screws are located in plain sight in the top
corners of the front cover, while the two lower front cover
corner mounting screws are located down in the front
“well” of the unit. Use a long-handled screwdriver to
remove them.
Perform the following steps to replace the ADH NETCOM
AC NEMA Automatic Air Dehydrator AC Power Supply
Module (23566)
1.
2.
3.
4.
The AC power supply module is located on the inside of
the front cover. If not already done, place a brace or prop
of some kind under the NEMA enclosure door to support
it during this procedure.
Using the nut driver, remove the four nuts and lock
washers securing the power supply module mounting
bracket to the Pem® studs inside the front cover. Refer to
Figure 2. Retain the mounting hardware.
5.
6.
MODEL ADH NEMA
AC POWER SUPPLY MODULE
REPLACEMENT PROCEDURE
Disconnect both of orange
Ethernet cable, then remove from
enclosure.
Loosen both captive
screws, then disconnect
connector.
Loosen screw & remove
ground wire.
Remove and retain the nuts and
lock washers from the four
corners of the bracket