Figure 1.A - DISCONNECTING THE ETHERNET CABLE,

THE POWER CABLE CONNECTOR, AND THE GROUND WIRE.

Figure 2. - THE AC POWER SUPPLY MODULE MOUNTING BRACKET.

Figure 1.B - DISCONNECTING THE ETHERNET CABLE,

THE POWER CABLE CONNECTOR, AND THE GROUND WIRE.

AC POWER SUPPLY MODULE REPLACEMENT PROCEDURE  |  PART NO. 

24732 

REV 

B.0

3

Shut off machine power by unplugging the unit.

Open the two front door latches, loosen the two captive 

screws in the corners of the housing opposite the 

hinges, then open the NEMA box. Place an object 

underneath the door once open to help support it 

during this procedure.

Remove the orange ethernet cable on the left by 

disconnecting both ends, then removing it. Set aside for 

re-use. Remove the power cable connector on the right 

by loosening the captive screw on each end of the green 

connector, then unplugging the connector. Disconnect 

the ground wire by loosening the ground wire retaining 

screw, then carefully removing the ground wire. Refer to 

Figures 1.A & 1.B.

Remove and retain the four mounting screws from the 

four corners of the protective front cover, then slowly lift 

the  front  cover,  carefully  flip  it  over,  then  set  it  down, 

upside down, to rest on the inside of the enclosure door. 

Be careful as there are still many wires connected 

between the enclosure and the front cover and there 

isn’t a lot of slack. Note that the two upper front cover 

mounting screws are located in plain sight in the top 

corners of the front cover, while the two lower front cover 

corner mounting screws are located down in the front 

“well” of the unit. Use a long-handled screwdriver to 

remove them.

Perform the following steps to replace the ADH NETCOM 

AC  NEMA  Automatic Air Dehydrator AC Power Supply 

Module (23566)

1.

2.

3.

4.

The AC power supply module is located on the inside of 

the front cover. If not already done, place a brace or prop 

of some kind under the NEMA enclosure door to support 

it during this procedure.

Using the nut driver, remove the four nuts and lock 

washers securing the power supply module mounting 

bracket to the Pem® studs inside the front cover. Refer to 

Figure 2. Retain the mounting hardware.

5.

6.

MODEL ADH NEMA

AC POWER SUPPLY MODULE

REPLACEMENT PROCEDURE

Disconnect both of orange 

Ethernet cable, then remove from 

enclosure.

 Loosen both captive

screws, then disconnect 

connector.

Loosen screw & remove 

ground wire.

Remove and retain the nuts and 

lock washers from the four 

corners of the bracket