background image

 5

A S S E m B ly   A n D   o p E r A t i n g   i n S t r u C t i o n S   |   e n E x H o - i C   -   F i r E   D E t E C t o r S

With your choice of ETHERMA you have decided on an inge-

nious  heating  solution.  We  thank  you  for  your  confidence.  In 

us you have a competent partner with more than 30 years of 
experience. ETHERMA relies on constant innovation , highest 
product quality and modern design.

We support you with comprehensive personalized services and 

find the right product solution for you.

The following instructions will help you, to use your ETHERMA 
quality product as effective as possible. They contain important 
information about safety, installation, use and maintenance of 
the devices. Please read the information in this instruction 
carefully and keep them for feedback at a later time on.

G E N E R A L   I N F O R M A T I O N

S p E C i F i C A t i o n S

Standby consumption: . . . . . . . . . . . . . . . . . . . . . . . . . . <0,5 mW

Consumption in alarm mode: . . . . . . . . . . . . . . . . . . . . . .<0,6 W

Emission band:   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 868MHz

Internal power supply: . . . . . . . . . . . . . . . . . . . . .  9-volt battery

External power supply:  . . . . . . . . . . . . . . . . . . . . . . . . 12 V (DC)

Head of detector:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A2S type

Magnetic test  |  Double LED alarm indicator  |  Pulse LED

This system has been carefully designed to be as effective 
as possible. There are some occasions, however, on which it 
cannot provide accurate detection. The operation of any kind 
of alarm system can be intentionally impeded or fail for other 
reasons, such as the following:

 › Improper installation. A security system must be properly in-

stalled to provide appropriate protection. This device should 
not be placed in locations where it could be exposed to hu-
midity or liquid from water sprinklers. Each installation must 
be evaluated to ensure that all areas are covered.

 › It is very important that the security system is serviced peri-

odically to ensure that it is in proper working order and parts 
must be updated or replaced if they are not providing the ex-
pected protection.

 › Power cuts. eNEXHO-IC requires an appropriate energy sup-

ply for proper operation. If the device is working on batteries, 
it is possible that they will fail. Even if the batteries do not fail, 
please make sure that they are in good condition and are in-
stalled properly. If the device is running on an external power 
supply, any outage, even of short duration, will interrupt the 
operation during the power cut. Power cuts of any duration 

are often accompanied by voltage fluctuations which can da

-

mage the device. Following a power outage, please perform 
a complete check of the system to ensure that it is working 
properly.

 › Discharged batteries. The lifetime of a battery depends on 

the environment in which it is found and on the number of 
activations of the device. Environmental conditions such as 

excessive humidity, high or low temperatures or abrupt tem-
perature changes can reduce the lifetime of the battery. Re-
gular inspections and maintenance will keep the system in 
good operational condition.

 › Sound alarm devices may not be heard by hearing-impaired 

people.

 › Phone line. The phone line could be out of order or busy for 

a while. An intruder may also attempt to sabotage it by me-

ans of sophisticated methods. This practice is very difficult 

to detect.

 ›

Insufficient time. In some circumstances, even if the device 

is working properly, it is possible that response measures 
are not taken in time to protect the occupants or their be-
longings.

 › Malfunction of a component. Despite utmost efforts to pro-

duce the most reliable system possible, it could fail on the 
grounds of the malfunction of a component.

 › Inadequate inspections. Most of the problems which cause 

malfunctions in a system can be detected by performing re-
gular checks and maintenance. The whole system should be 
tested on a weekly basis and immediately after any intrusion 

or intrusion attempt, fire, storm, earthquake, accident or any 

kind of building works.

 › Security and insurance. Despite all its advantages, an alarm 

system is not a substitute for home or life insurance. An 
alarm system does not exempt the user from taking precau-
tions regarding  prevention and minimisation of damages in 
an emergency situation.

W A r n i n g

Assembly and operating instructions

 › Please read these instructions carefully and keep them for future consultation. eNEXHO range equipment must be installed 

by an accredited, qualified electrician and must observe Low Voltage Regulations. The installation as a whole should meet the 

provisions of aforesaid regulation. Any claim presented will be deemed invalid if the prevailing regulations have not been met.

eNEXHO-IC

Fire detectors

Содержание eNEXHO-IC

Страница 1: ...eNEXHO Anlagen sollte von einem qualifizierten zugelassenen Elektroinstallateur ordnungsgem nach der gelten den Niederspannungsrichtlinie durchgef hrt werden Die gesamte Anlage sollte den Bestimmunge...

Страница 2: ...sehr wichtig dass das Sicherheitssystem regelm ig gewartet wird Auf diese Weise kann sichergestellt wer den dass es leistungsf hig bleibt und Teile ggf aktualisiert oder ersetzt werden wenn sie nicht...

Страница 3: ...in die Spreizd bel ein Halten Sie den Tastkopf von unten gegen die Decke indem Sie die Schraubenk pfe die von der Decke aus nach unten zeigen durch die Aussparungen stecken die Ihnen vorher zur Marki...

Страница 4: ...ines eNEXHO Systems ist ber die Anzeige des Internet Moduls eNEXHO NT dar ber in formiert werden wenn die Batterie eines der Ger te bald verbraucht ist Wenn der Feuermelder in einem eNEXHO Hausau toma...

Страница 5: ...external power supply any outage even of short duration will interrupt the operation during the power cut Power cuts of any duration are often accompanied by voltage fluctuations which can da mage the...

Страница 6: ...the snap Respecting the polarity join the two terminals of the power supply with the two wires that were previously connected to the snap To close the eNEXHO IC fire detector align the arrow that is...

Страница 7: ...lows you to perform a magnetic test to check the proper functioning of the device In order to perform a test hold a magnet to the pilot light of the device head At this point all device warning light...

Страница 8: ...schland Fabrikstra e 3 D 48599 Gronau Tel 49 0 25 62 81 97 00 Fax 49 0 25 62 81 62 90 Web www etherma com Mail office de etherma com e N E X H O I C Name des H ndlers Distributed by Kaufdatum Purchase...

Отзывы: