- 64 -
From the point of view of the inputs and outputs to the electric module :
If
= Input
Then
= Output
Closed
= current passes
Open
= no current passes
Live
= +12V
Stop
= 0V
Initial stage :
Input : horizontal flap contactor = closed
Input :
mobile basket contactor = closed
Input :
fixed basket contactor = closed
Opening
Input : switch opening mobile basket = closed
1) Output : flap closing coil = live
2) Input :
horizontal flap contactor = open
3) Output : revolving warning light = live / flap closing coil = live
basket opening coil = live / (blade clutch = stop*)
Input : mobile basket opening switch = open
Closing
Input : mobile basket closing switch = closed
1) Output : flap closing coil = live
2) Input :
vertical flap contactor = closed
3) Output : flap closing coil = live / basket closing coil = live
4) Input :
mobile basket contactor = closed (and fixed basket contactor = closed)
5) Output : (blade clutch = live*) / flap opening coil = live
6) Input :
horizontal flap contactor= closed
7) Output : revolving warning light = stop.
Input : mobile basket closing switch = open
(*If the blades were in operation when emptying was begun.)
Содержание HYDRO 124D
Страница 1: ......
Страница 2: ...2...
Страница 4: ...4 GRASSBOX...
Страница 5: ...5...
Страница 8: ...8 POWER CURVES CONSUMPTION TORQUE LUBRICATION...
Страница 9: ...9 AIR SUPPLY CIRCUIT COMBUSTION AIR FILTER...
Страница 11: ...11 ENGINE HOT...
Страница 17: ...17...
Страница 48: ...48 OIL RETURN FILTER H124D...
Страница 50: ...50 DRIVE TRANSMISSION CIRCUIT HYDRAULIC DIAGRAM...
Страница 51: ...51...
Страница 52: ...52...
Страница 71: ...71...
Страница 73: ...73...