12
Etesia robots indicate their status with beeps or with messages on the display.
The ETB charge unit also indicates its status with a two coloured LED.
ROBOT
STATION
Beeps
LED
-
1 long beep:
stop machine, or mistake on the keypad
-
1 short beep:
action on a key
-
2 long beeps / 10 sec:
charge robot
-
2 short beeps / 1sec:
cutter head starting
-
1 short beep / 2sec:
alarm
-
Green blink:
OK, normal mode
-
Red blink:
cut perimeter wire or wire too long
(normally > 1200m)
-
Continuous red LED:
faulty electronic base unit card or
wire too short (normally < 200m)
-
Not lit:
base unit switched off
Charge
-
FC:
Fast Charge, normal mode
-
SC:
Slow Charge, rest
-
WU:
Wait User
-
WT:
Wait programmed Timers
-
W.BH:
Wait Battery too Hot
-
W.FT:
Wait Freezing ambient Temperature
CODE
MEANINGS
REMARKS
Al01→→Al31
Blocked head(s) (1, 2, 3, 4, 5)
Indication on the screen
→ Check the cutting components
Al32→→Al35
Left and/or right wheel blocked
Indication on the screen
Al36→→Al39
Body in left and/or right collision
Impact sensors
→ Check the bo
dy impact components
Al40→→Al43
Tactile sensor (touch flange) in left and/or right
collision
Touch tyre flange
→ Check the red pressure gauge connected in the
box
Al44
Code expired
Follow the code entering procedure
Al45
Battery too discharged
→ Put the machine on the station manually, and start
it again manually 2 hours later
Al46
No peripheral signal
Check at the charging station
Al47
Station not found
The machine has not found its station after a tour of
the terrain (function of the P01)
→ Check P01, verify sonar machine (if it slowed
down), check the sonar station (if the machine
slowed down on approaching the station)
Al48
Outside wire boundary
→ Check O03: demo mode; O08: inversion phase;
P00: intensity at 30
Al49
Wire lost
The machine stops when seeking its wire after 6 m.
Al50
No way out path
Blocked at this location after several close
manoeuvres
Al51
Slipping
Distance travelled greater than P01
→ Check the state of the terrain, check P01
Al52
Blocked on wire
→ Check O08: investment phase
Al53
Fuse. Power surge
Battery fuse broken OR main switch on OFF when
charging
Al55
Loss of Charging?
Loss of charging on the station
Al56
Charge contact?
The machine has detected the station but has not
been in contact with the station
Al57
Bat Temp Sensor
Problem with the temperature sensor
5• SAFETY ALERT: ERROR MESSAGE
Содержание ET MOWER ETM105
Страница 1: ...ETM105 ET MOWER GB Original user manual Please read carefully before using your machine...
Страница 5: ...5 1 KEY TO DIAGRAMS...
Страница 14: ......
Страница 16: ...11 17 17 7b 6b 6a 7a 8 9 7c 10 10a 10b 10c 10d 11a 16 2 PICTURES...
Страница 17: ...12 13 19 17 15 16 14 18 17 2 PICTURES...
Страница 18: ...28 27 26 25 24 23 22 20 21 30 29 31 18 67 cm 67 cm 2 PICTURES ETBA...
Страница 39: ......
Страница 55: ...ETESIA SERVICE GARANTIE 13 rue de l Industrie 67165 WISSEMBOURG CEDEX France Stamp here please...