Manifold Gas Pressure should be adjusted on low and high
re.
If gas supply pressure drops below 3.5" WC unit will not have enough gas volume for max
re!
□
□
HOW TO CHECK GAS SUPPLY PRESSURE
HOW TO CHECK MINIMUM MANIFOLD GAS PRESSURE
Check manometer reading of low
re manifold pressure against unit combustion speci
cations.
Turn off power source and turn off gas supply to the unit.
Remove the front cover from the unit.
Loosen the gas supply pressure test port screw and connect manometer to this port; turn on the gas to the
water heater.
Turn the water heater on and open multiple taps to force unit into high
re; check gas supply pressure at the
test port with a manometer with unit in high
re.
Turn the water heater ON with 2gpm of hot water
owing.
Set the dip switch group 3 and number 3 ON.
1.
1.
2.
2.
3.
4.
Figure 1:
The gas valve is designed with both test ports for gas supply pressure and manifold pressure to the unit. Refer to
above Figure of the test ports on the gas valve.
GAS MANIFOLD & SUPPLY PRESSURE
Manifold pressure:
GU145(S) : 0.1" min, 1.7" max.
GU195(S,M) : 0.1" min, 3.2" max.
Supply pressure:
GU145(S) / GU195(S,M) : NG3.5 - 10.5", LP8.0 - 14" w.c.
NOTICE
NOTICE
WARNING
!
!
!
!
!
!
Gas supply pressure
Adjustment Screw for
Minimum Pressure
Gas manifold pressure
Adjustment Screw for Maximum Pressure
Содержание GU145 Series
Страница 5: ...5 Dimensions GU145 S 508 11 12 21 22 1145 S GU195 S M 508 11 12 21 22 1195 S M...
Страница 6: ...6 Parts Diagram for Model GU145 S 508 11 12 21 22 1145 S GU195 S M 508 11 12 21 22 1195 S M...
Страница 7: ...7 Parts Diagram for Model GU145 S 508 11 12 21 22 1145 S...
Страница 48: ...48 DIAGNOSTICS Before calling for service review the following diagnostic steps rst for saving time and money...
Страница 53: ...53 Wiring and Connection Diagram Wiring Diagram MODEL GU195 M 508 11 12 21 22 1195 M...