12

Installation Preparation

Unpack the unit carefully and make sure that all accessories are put aside so that they will not be lost.

 Operator's manual   

 Warranty Registration Card   

 Included Parts

Inspect the water heater for possible shipping damages.

Check  the  markings  of  the  rating  plate  on  the  water  heater  to  be  certain  the  type  of  gas  being  furnished 
corresponds to what the water heater is equipped for.
Do not connect this water heater to a fuel type not in accordance with the rating plate.

Carefully choose the location for the new heater as placement is a very important consideration for the safety of 
the occupants in the building and for the most economical use of the appliance.
Whether replacing an old water heater or putting the water heater in a new location, consider the following critical 
points:    

Read the Safety guidelines in the beginning of this manual.
The internal computer controlled regulator is preset by the manufacturer and should not be adjusted by user.
Maintain proper space around the unit for servicing. Install the unit so that it can be connected or removed 
easily.
The electrical connection requires a means for switching off the power supply.
Avoid installing the unit in an area with high levels of dust, sand, or debris. These particles may clog the air 
vent or impair the function of the fan, leading to improper combustion. Regular maintenance is needed.
Do not install the unit where the exhaust vent is pointing into any opening in a building or where the noise may 
disturb neighbors.

The location selected should be as close to the vent termination point as possible, and centered within the 
water piping system for best hot water delivery. All water heaters can leak. Do not install without adequate 
drainage provisions where water flow can cause property damage.
If vented through an outside wall or through the roof using 3" vent piping the total vent run cannot exceed 95 
feet with one 90

°

 elbow. If more elbows are required the venting distance must be reduced 5 feet for every 90

°

 

elbow.
Vent piping should slope downward towards the unit. Horizontal runs require adequate support at 3

½

 feet 

intervals and vertical runs supported at 5 feet intervals.
Condensation may be created at times as the combustion gases exit the vent cap. Discoloration of surfaces in 
proximity to the vent cap may occur.

Unpacking Your Eternal Water Heater

Additional Safety Instructions

WATER HEATER PLACEMENT




Before Commencing The Installation

Check that it is in accordance with relevant building and mechanical codes, as well as any local or state or 
federal regulations.

WARNING

The appliance should be located in an area where leakage of the tank or connections will not result in damage 
to the  area  adjacent  to  the  appliance  or to  lower  floors  of  the  structure.  When  such locations  cannot be 
avoided, it is recommended that a suitable drain pan be installed under the appliance. The pan must not restrict 
combustion air 

 ow.

The minimum inlet gas pressure must be within the value speci

 ed by the manufacturer and the minimum value 

listed is only for the purpose of input adjustment.
If a water heater is installed in closed water supply system, such as one having a back

 ow preventer in the 

cold water supply line and a thermal expansion tank is required, contact the water supplier or local plumbing 
inspector on how to control this situation.
The Temperature and Pressure (T&P) relief valve must be certi

 ed as meeting the requirement of the Standard 

for Relief Valves and Automatic Gas Shut-off  Devices  for  Hot Water  Supply Systems ANSI Z21.22/CAN1-
4.4. The valve must be marked with a maximum set pressure not to exceed the marked hydrostatic working 
pressure of the water heater (150 psi) and a discharge capacity not less than the water heater input rate as 
marked on the rating plate. 

WARNING

CAUTION

!

!

!

!

Содержание GU145 Series

Страница 1: ...maintained Failure to follow these instructions exactly could result in a re or explosion serious bodily injury and or property damage Do not store or use gasoline or other ammable vapors and liquids...

Страница 2: ...entric Vent Kit Outdoor Vent Kit Installation P25 Vent Pipe Installation Terminator Position P26 Gas Supply Piping P27 LP Conversion P28 Water Supply Connection P29 Condensate Piping P30 Temperature a...

Страница 3: ...3 Included Accessories Optional Accessories 0 75mm 2C Wire Hole Plug 1pcs Self Tapping Screw 5 32 x 5 8 2pcs Cap 2pcs Philips Head Screw M8x15 4pcs...

Страница 4: ...jection Metal Fiber Infrared Gas Valve System Dual Stage Negative Pressure Full Modulation Air Ratio Internal Piping Material Standard Copper S Option 316L SS M Option 316L SS MCU Reserve Tank Under 2...

Страница 5: ...5 Dimensions GU145 S 508 11 12 21 22 1145 S GU195 S M 508 11 12 21 22 1195 S M...

Страница 6: ...6 Parts Diagram for Model GU145 S 508 11 12 21 22 1145 S GU195 S M 508 11 12 21 22 1195 S M...

Страница 7: ...7 Parts Diagram for Model GU145 S 508 11 12 21 22 1145 S...

Страница 8: ...ollar Packing 13 Rubber Foot 14 Drain Valve Assembly 15 Main Power Cord 16 Handle 17 Condensing Nipple 18 Plug 19 Mesh Screen 20 Outdoor Venting Cap Optional 21 Trap Cleaner Assembly 22 Radial Blower...

Страница 9: ...9 Parts Diagram for Model GU195 S 508 11 12 21 22 1195 S Parts Diagram for Model GU195 M 508 11 12 21 22 1195 M...

Страница 10: ...lve Cash Acme 11 Vent Collar 12 Vent Collar Packing 13 Rubber Foot 14 Drain Valve Assembly 15 Main Power Cord 16 Handle 17 Condensing Nipple 18 Plug 19 Mesh Screen 20 Outdoor Venting Cap Optional 21 T...

Страница 11: ...matically lights the burner Do not try to light the burner by hand Smell all around the water heater area for evidence of leaking gas Be sure to smell next to the oor because LP gas is heavier than ai...

Страница 12: ...through an outside wall or through the roof using 3 vent piping the total vent run cannot exceed 95 feet with one 90 elbow If more elbows are required the venting distance must be reduced 5 feet for...

Страница 13: ...n When this occurs the trap must be cleaned CLEAN OUT OF TRAP The condensate trap must be lled with water prior to using the water heater Fill 3 0 oz water through exhaust collar per gure 1 Eternal wa...

Страница 14: ...ng should give a minimum free area of one square inch per 15 000 Btu hour of the total input ratings of all appliances in the enclosed area When combustion air is supplied from inside the building eac...

Страница 15: ...of the appliance Locate the water heater in an open unroofed area and maintain the above minimum clearances from combustible materials Exhaust Ventilation Do not have the ue terminal pointing toward...

Страница 16: ...nstallation of water heaters in manufactured homes mobile homes and Recreational Park Trailers In the absence of such a standard the water heater should be installed in accordance with the latest edit...

Страница 17: ...f the framing is not standard or installing on an uneven surface fasten 3 4 plywood to the stud wall and then attach the wall bracket Hang the unit on the mounted wall bracket and secure bottom of the...

Страница 18: ...must be elevated at least 6 off the floor This mounting clearance provides access for clearing any possible debris or accumulated water seepage that can occur below the unit Install the unit on Eterna...

Страница 19: ...n vent with the vent pipe of any other water heater or appliance NOTICE VENTING GUIDELINES This water heater must be properly vented for removal of exhaust gases to the outside atmosphere Correct inst...

Страница 20: ...to the intake collar for future serviceability Reduce the maximum allowable length for each elbow used as follows 45 degree elbow Deduct 2 feet 90 degree elbow Deduct 5 feet How To Con gure Unit For P...

Страница 21: ...xisting vent piping or chimney The total vertical and horizontal runs cannot exceed the maximum length with a maximum number of 90 degree elbows as speci ed in the table of page 20 Eternal can be vent...

Страница 22: ...pipe Vent pipe must exit exterior wall horizontally only Place the 1 2 metal mesh screen inside the terminal tting and connect it as shown to the vent pipe on the exterior of the building Seal any op...

Страница 23: ...lly vented but next unit vent ternination must be at least 12 inches away from the first unit It is important that vent terminatiion to avoid recirculation of flue gases Concentric Multivent Terminati...

Страница 24: ...The connection for the flue gas and air intake system can be positioned on the right as well as on the left side of multi control units Direct Vent Sealed Vent Multi Units With Common Vent POWER VENT...

Страница 25: ...ccur and may cause intermittent operation WARNING Outdoor Vent Kit Philips Head Screw M4xL8x6pcs Intake louvers Exhaust Installations must be made with a vent pipe system certi ed to ULC S636 The rst...

Страница 26: ...Clearance to each side of center line extended above meter regulator assembly 3 feet within a height 15 feet above the meter regulator assembly I Clearance to service regulator vent outlet 3 feet J C...

Страница 27: ...inish and it would not be able to reach maximum performance Size gas piping system correctly following ANSI Z223 1 NFPA 54 or by local code Based on 0 60 specific gravity for natural gas at 0 5 W C pr...

Страница 28: ...13 w c maximum pressure Contact the local propane gas supplier for recommended sizing of piping tanks and 100 lockup gas regulator NOTICE 5 Reassemble front panel and apply LP label Prior to start up...

Страница 29: ...ING Close water supply shut off valve to the unit rst Connect garden hose to the draining valve located on the lower leftsider of the unit Open the valve by using a at head screw driver to drain water...

Страница 30: ...nearest drain is above the water heater will require the use of a condensate pump Size the pump to allow for a maximum condensate discharge of 2 GPH from the water heater Horizontal runs must be slop...

Страница 31: ...te Internal Pump Control Function Step 1 Push 1 switch of group 2 like below gure Step 1 Unplug power cord of unit Step 2 Make the hole on right side of panel and get rid of burr Step 3 Insert the pum...

Страница 32: ...A battery back up may be used to supply hot water during periods of power outages We recommend a computer grade UPS uninterruptable power supply with at least 600VA rating for extened coverage Ground...

Страница 33: ...ng 5 screws 3 Open one of the pre cut holes on either side panels of the unit and insert the hole plug 1 Open the main controller PCB cover by removing 1 screw 2 Run wire from the PCB to where the rem...

Страница 34: ...of the remote display by loosening 2 screws Secure the Remote controller to the Wall Anchors using the included Mounting Screw 2 pcs and replace the cover to hide the mounting hardware Remote Display...

Страница 35: ...NBUS Protocol ensures good communication between units Alternate Host Firing distributes wear and tear across all units every 24 hours Redundancy program allows remaining units to work when a units br...

Страница 36: ...power outlet 1 Make sure dip switch 4 to ON position Group 1 No 4 2 Make sure dip switch 6 7 8 OFF position Group 2 No 6 7 8 3 When this switch is on CAN Control Area Network engine is enable and all...

Страница 37: ...Installation Operating as a single unit Eternal consumes less than 1A current and the power supplied to unit can be on as low as 2A capacity However when multiple Eternals are used together power sup...

Страница 38: ...tion System with an Eternal Water Heater Single Eternal with Storage Back up These diagrams are for reference as basic guides Each installation should be engineered properly and compliant to Local and...

Страница 39: ...culation with 2 Units manifold Single Eternal with pre heater i e Solar These diagrams are for reference as basic guides Each installation should be engineered properly and compliant to Local and Stat...

Страница 40: ...m with Multiple Units Connection Multiple Units Connection with Storage Back Up These diagrams are for reference as basic guides Each installation should be engineered properly and compliant to Local...

Страница 41: ...stat pump and set at 20 F below Eternal temperature setting If unit is not controlling pump by internal relay Size the pump to provide a minimum of 5 0GPM through the system at 10ft of head plus pipin...

Страница 42: ...s piped so that its outlet will be farthest from the hot water supply line NOTICE Reverse return system In above drawing there is no path of least resistance water flow will be adequate in each unit R...

Страница 43: ...inlet water tubing size 3 4 inches Has a combined T P relief valve been installed Does this valve have a discharge line installed and is it piped to a free owing drain Have all the plumbing connection...

Страница 44: ...pening the nearest hot water faucet Allow water to run until a constant ow is obtained This will let air out of the water heater and piping Open a hot water tap to check that water will ow to that tap...

Страница 45: ...re setting is only adjustable when the burner is not in use The maximum water temperature setting can be limited by DIP switches This manual setting overrides adjustable temperature settings on the fr...

Страница 46: ...st the water temperature Press the either the Hotter up or Cooler down temperature setting button with the unit ON temperature setting is only adjustable when the burner is not in use To lock the cont...

Страница 47: ...pection A visual inspection should be made on the venting system at least once a year Clean Up The ue outlet and the air intake hole on the top of the water heater should be checked Clean as needed to...

Страница 48: ...48 DIAGNOSTICS Before calling for service review the following diagnostic steps rst for saving time and money...

Страница 49: ...wn operation continuously If an error occurs a message will flash on the digital monitor of the front panel This assists with diagnosing the error and may enable you to overcome a problem without a se...

Страница 50: ...p OFF then ON again If this does not clear the Error Message try pushing the ON OFF button OFF then ON again If the Error Message still remains contact our service center or your nearest service agent...

Страница 51: ...to the water heater Turn the water heater on and open multiple taps to force unit into high re check gas supply pressure at the test port with a manometer with unit in high re Turn the water heater ON...

Страница 52: ...52 Wiring and Connection Diagram Wiring Diagram MODEL GU145 S 508 11 12 21 22 1145 S GU195 S 508 11 12 21 22 1195 S...

Страница 53: ...53 Wiring and Connection Diagram Wiring Diagram MODEL GU195 M 508 11 12 21 22 1195 M...

Страница 54: ...licable codes must be followed or property damage severe injury or death can result Failure to use a licensed plumber or contractor follow venting plumbing and building codes or follow installation in...

Отзывы: