28
LP Conversion
How to convert to LP
1. Remove front panel by loosening 5 screws.
2. Locate the gas valve towards lower left of the unit.
3. Loosen nut connecting gas tube to gas valve.
4. Insert LP orifice into the nozzle, retighten gas tube
and make sure no gas leak.
Screws
Adjust the propane supply regulator provided by the gas supplier for 13" w.c. maximum pressure.
□
Contact the local propane gas supplier for recommended sizing of piping, tanks and 100% lockup gas regulator.
NOTICE
!
!
5. Reassemble front panel and apply LP label.
Prior to start up, ensure the unit is set to
re propane.
Check the rating label for the type of fuel. If there is a
con
ict or doubt on the setup, remove the gas valve
and check for the propane ori
ce. Failure to ensure
proper setup could result in severe personal injury,
death or substantial property damage.
WARNING
!
!
Gas Valve
LP label
Nut
Gas Tube
LP Ori
ce