Страница 2: ...I Electrical Signs 3 Ⅲ Technical Specifications 3 Ⅳ Structure 4 Ⅴ LCD Display 4 Ⅵ Operating Method 4 1 Start up Shutdown 4 2 Calibration 4 4 Hold Storage Access Reading and Deleting 5 5 Data Upload 5 Ⅶ How to Change Battery 6 Ⅷ Accessories 6 ...

Страница 3: ...e it and seal it for safekeeping immediately and then send it for disposal of authorized agency u Users shall carry out operation based on danger signs on leaker and manual u Users shall carry out safety operation based on instructions listed in this manual e g and danger signs on this manual I Introduction ETCR6000 AC DC Clamp Leaker is specially designed for measurement of AC DC current by adopt...

Страница 4: ...ng Rate 2 times s Frequency AC 45Hz 400Hz Polarity Indication DC current auto identified and display Test Position Tested wire in the jaw center Range Shift Automatically Line Voltage AC600V RS232 Interface Data stored in the memory of the meter via RS232 upload to PC Com Configure Baud rate 9600 data bit 8 stop bit 1 Data Memory 99units FULL blinks when the memory is full Reading Hold DH indicati...

Страница 5: ...the leaker will shut down automatically after flickering for 30s it will shut down formally to reduce battery consumption In case you have pressed HOLD key when LCD was flickering the leaker will continue to work for 5 minutes If the tester power off automatically the gear should firstly be switched to OFF for power on next time 2 Calibration When measuring first choose AC or DC gear adjust ZERO k...

Страница 6: ...a and automatically stored in the memory with a code press HOLD key again to release the hold state and the leaker continues its measuring in case stored data reached to 60 groups press HOLD key again the FULL symbol will display which means storage memory is full press HOLD key to cancel FULL flickering and return to measuring mode 2 Long press HOLD key to enter into data access mode and display ...

Страница 7: ...t off the battery to storage 1 symbol means the battery is undercharge and need to be replaced 2 Shut down the leaker before opening the battery cover please confirm the leaker is in off position and then replace with qualified new battery special attention shall be paid to polarity of battery at last cover battery cover plate Ⅷ Accessories Clamp tester 1 pc RS232 Com cable 1 pc Software 1 disk Ba...

Страница 8: ...CR Electronic Technology Company Address F 3F No 4 Pengshang Zhifu Road Jiahe Baiyun District Guangzhou Guangdong China Post Code 510440 Tel 86 20 62199556 62199553 Fax 86 20 62199550 E mail info etcr cc Website www etcr cc ...