![Etco IP-Mini Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/etco/ip-mini/ip-mini_instruction-manual_2431813022.webp)
ETCO
Incorporated, Tel: 401-467-2400 Fax: 401-467-9230 Web: www.etco.com
SECTION 2
CRIMP INSPECTION AND MEASUREMENT
ETCO
MX MINI REAR FEED APPLICATOR - page
5
2
TERMINAL CRIMP CRITERIA
9
• All wire strands should be enveloped by the crimp wings.
• All wire strands should be uniformly deformed and evenly
distributed on both sides of the crimp.
• The wire strand honeycomb-like structure shall have
minimal cavities/voids.
• Barrel shape shall be relatively symmetrical and the seam
shall be closed.
• The crimp should not cut any wire strands due to
over-crimping or inadequate bellmouth.