TurboRay User Manual
LED Driver 1 NR
This message displays after the reset of the fixture if any of the following conditions exist:
•
the driver board has malfunctioned
•
the driver board power or data wire harness is disconnected or damaged
LED Driver 2 NR
This message displays after the reset of the fixture if any of the following conditions exist:
•
the driver board has malfunctioned
•
the driver board power or data wire harness is disconnected or damaged
Pan and Tilt NR
This message displays after the reset of the fixture if any of the following conditions exist:
•
the driver board has malfunctioned
•
the driver board power or data wire harness is disconnected or damaged
Pan Driver Fault
This message displays after the reset of the fixture if any of the following conditions exist:
•
the pan driver board is above operating temperature
•
the driver board power or data wire harness is disconnected or damaged
Pan Encoder
This message displays after the reset of the fixture if any of the following conditions exist:
•
the pan lock is engaged
•
the magnetic encoder has malfunctioned
•
the motor driver circuit has malfunctioned
•
the drive motor has malfunctioned
•
the motor or encoder wire harness is disconnected or damaged
Pan Encoder Time Out
This message displays after the reset of the fixture if any of the following conditions exist:
•
there is an obstruction preventing the unit from correcting itself within 20 seconds
•
the pan lock is engaged
•
the magnetic encoder has malfunctioned
•
the encoder wire harness is disconnected or damaged
Pan Sensor
This message displays after the reset of the fixture if any of the following conditions exist:
•
the Hall sensor has malfunctioned
•
the magnet for the Hall sensor is missing
•
the motor or sensor wire harness is disconnected or damaged
•
the drive motor has malfunctioned
•
the drive motor circuit has malfunctioned
•
the pan belt is broken