Cleaning the Reflector

To quickly clean the reflector, remove the lens tube and clean the dust from the reflector with a blast 

of oil-free air. You may also wipe the reflector with a clean lint-free cloth. If either method is not 

sufficient, follow these steps.

Step 1:

To protect the lamp housing during cleaning, remove the lamp housing by loosening the 

knurled bolt and pulling the housing straight out. See 

Figure 3

.

Step 2:

Remove the barrel rotation knob located at the bottom of the barrel (see 

Figure 1

). Use 

a Phillips screwdriver to remove the retainer bolt located on top of the reflector housing.

Step 3:

Rotate the barrel 45° in either direction. Carefully remove the barrel from the reflector 

housing.

Step 4:

Remove dust with a blast of oil-free air or wipe with a clean, lint-free cloth. Isopropyl 

alcohol, distilled water or a 50%-50% mixture of each can be used to clean the glass 

surface.

Step 5:

Gently wipe the reflector.

Step 6:

Insert the barrel into the reflector housing with the iris/pattern slot on top. Align the 

triangles on both parts.

Step 7:

While gently pressing in, rotate the barrel 45° clockwise until it sets into position, then 

rotate the barrel counterclockwise 45°. The barrel should be firmly attached and the 

triangles should be aligned.

Step 8:

Reinstall the barrel rotation knob and tighten the retainer bolt.

Step 9:

Reinstall the lamp housing and tighten the knurled bolt.

Portable appliance test (PAT)

The Portable Appliance Test is a set of tests that must be administered to electrical equipment in 

the UK and some locations in Europe to ensure safety.The tests are typically carried out using a 

small PAT device. The PAT device connects to a power source and then attaches to the product 

via an electrical outlet and test probes. The PAT provides a simple pass or fail result, allowing rapid 

testing of large inventories.

Source Four CE luminaires include a specific PAT point where the test clip is attached, as shown 

in 

Figure 15

. PAT tests should be performed by a qualified technician. Your local regulatory 

authority has guidelines on the testing frequency. 

W A R N I N G :

Unplug the luminaire before attempting to clean the reflector.

Figure 15

PAT device 

connection point

Содержание Source Four Zoom CE

Страница 1: ...tronic Theatre Controls Inc All Rights reserved Product information and specifications subject to change Part Number 7060M1260 06 01 Rev A Released August 2007 CE User Manual Production Dates Septembe...

Страница 2: ...rked are the property of their respective owners ETC intends this document whether printed or electronic to be provided in its entirety Declaration of conformity 1 Source Four Zoom CE guidelines 2 Bas...

Страница 3: ...2 17 1990 Specification for luminaires for stage lighting television film and photographic studios outside and indoor equiv BS 4533 102 17 1990 following the provisions of EU LV Directive s 73 23 EEC...

Страница 4: ...ternal cable is damaged it shall be replaced by ETC or our service agents Always hang the Source Four Zoom CE with the colour frame held securely behind the retaining clip Always replace the lamp if i...

Страница 5: ...safety warnings before use Do not mount the luminaire on or near combustible surfaces Do not operate the luminaire without a lens installed Always hang the luminaire with the color frame retaining cli...

Страница 6: ...5 230 375 230 7 250 3 000 K 1000 hours HPL 750 2240 750 240 19 750 3 200 K 300 hours HPL 750 240X 750 240 15 600 3 050 K 1500 hours HPL 575 240 575 240 14 900 3 050 K 400 hours HPL 575 240X 575 240 11...

Страница 7: ...e knurled bolt Note Verify that the HPL lamp you intend to install is suitable for your facility s voltage 115 120 230 and 240 volt HPL lamps are available See HPL lamp table page 4 Operating HPL lamp...

Страница 8: ...nner knob either clockwise or counterclockwise to achieve an optimum flat field See Figure 5 Selecting the field angle and focusing the beam Step 1 Press the locking lever push button and lift the loc...

Страница 9: ...h two screws prevents light leakage see Figure 8 Step 1 Use a screwdriver to loosen the screws on the drop in iris slot cover Do not remove thumbscrews Step 2 Slide the cover completely forward to exp...

Страница 10: ...ace Setting the luminaire height within the yoke The Source Four 25 50 Zoom has a two position yoke for modifying the overall height in which the luminaire is mounted see Figure 10 To change the heigh...

Страница 11: ...yoke for setting the fixture s angle Setting the balance yoke Step 1 Loosen the balance yoke s clutch hex bolts on either side of the luminaire Step 2 Adjust the balance yoke so it is perpendicular to...

Страница 12: ...n lint free cloth Isopropyl alcohol distilled water or a 50 50 mixture of each can be used to clean the glass surface Step 4 Starting from the center gently wipe the lens Step 5 Close the extrusion do...

Страница 13: ...is pattern slot on top Align the triangles on both parts Step 7 While gently pressing in rotate the barrel 45 clockwise until it sets into position then rotate the barrel counterclockwise 45 The barre...

Страница 14: ...12 Source Four Zoom CE User Manual English...

Страница 15: ...13 English...

Страница 16: ...06 32 656 990 Holzkirchen DE Ohmstrasse 3 83607 Holzkirchen Germany Tel 49 80 24 47 00 0 Fax 49 80 24 47 00 3 00 Hong Kong Rm 1801 18 F Tower 1 Phase 1 Enterprise Square 9 Sheung Yuet Road Kowloon Ba...

Отзывы: