4
CEM3 Rack Retrofit Manual
Unpack and Organize
The table below lists the parts and components needed to retrofit a rack (SR+ or HSR+ 6, 12,
24, or 48) to become a Sensor3 rack with a CEM3.
Bag
Parts/Components
ETC Part Number
SR+ Enclosure
7141K1101
HSR+ Enclosure
7141K1004
1
CEM+ to CEM3 Backplane Power Adapter
Harness
7141B7007
1
1
Cable tie 4" Hi-temp Black
HW7121
8
8
Tie-mount (sticky-back)
HW741
4
4
Sensor3 Beacon Door Acrylic
7141A4050
1
1
2
Screw 6-32 X 3/8 Ph PH MS CP W/Patch
HW222
3
3
Screw 8-32 X 3/8 Ph PH MS CP W/Patch
HW377
3
3
CEM3 Backplane 1/8” #8 screw spacer
HW9343
3
3
3
CEM3 Beacon Assembly
7140B5620
1
1
-
Sensor3 ESR/HSR Install Enclosure Backplane
Assembly
7144A2100-CFG
-
1
-
Sensor3 SR Install Enclosure Backplane Assembly
7141A2103-CFG
1
-
-
Sensor3 Installation Rack Door Label
7141A4049
1
1
Additional Items
Sensor3 AF Card (Optional)
7150B5623
up to 4*
CEM3
7140A1000
1
Required Tools
#1 Phillips screwdriver
#2 Phillips screwdriver
1/4” flat head screwdriver
Diagonal wire cutter
Permanent marker
Wire strippers