background image

Introduction

3

Help from ETC Technical Services

If you are having difficulties, and your problem is not addressed by this document, try the ETC 
support website at 

support.etcconnect.com

 or the main ETC website at 

etcconnect.com

. If 

none of these resources are sufficient, contact ETC Technical Services directly at one of the 
offices identified below. Emergency service is available from all ETC offices outside of normal 
business hours.

When calling for help, take these steps first:

• Prepare a detailed description of the problem
• Go near the equipment for troubleshooting
• Find your notification number if you have called in previously

ETC, Inc.

Americas

Technical Services Department

3031 Pleasant View Road

Middleton, WI 53562

800-775-4382 (USA, toll-free)

+1-608 831-4116

[email protected]

ETC GmbH

Germany, Austria, Switzerland, Eastern 
Europe, and Russia

Technical Services Department

Ohmstrasse 3

83607 Holzkirchen, Germany

+49 (80 24) 47 00-0

[email protected]

ETC Austin

High End Systems Products

Technical Services Department

2105 Gracy Farms Lane

Austin, TX 78758 USA

800-890-8989 (USA, toll-free)

+1-512 836-2242

[email protected]

ETC France

France

Zone Urbaparc -

Bâtiment E

6 Boulevard de la Libération

Saint-Denis, 93200

+33 1 4243 3535

[email protected]

ETC Ltd

Europe, Middle East, and Africa

Technical Services Department

26-28 Victoria Industrial Estate

Victoria Road,

London W3 6UU England

+44 (0)20 8896 1000

[email protected]

ETC Asia

Asia

Technical Services Department

Room 1801, 18/F

Tower 1, Phase 1 Enterprise Square

9 Sheung Yuet Road

Kowloon Bay, Kowloon, Hong Kong

+852 2799 1220

[email protected]

Содержание Sensor+ HSR+ Series

Страница 1: ...Part Number 7141M2300 Rev C Released 2021 03 Sensor Enclosure SR HSR Series CEM to CEM3 Retrofit Manual...

Страница 2: ...ademarks and patents go to etcconnect com ip All other trademarks both marked and not marked are the property of their respective owners ETC intends this document whether printed or electronic to be p...

Страница 3: ...move the Old CEM page 6 Label and remove the existing equipment Attach New Power Harness page 7 Adapt and connect the power harness for the new backplane Install the New Backplane page 9 Transfer the...

Страница 4: ...ccur people may be harmed or there are serious or dangerous consequences of an action WARNING RISK OF ELECTRIC SHOCK This warning statement indicates situations where there is a risk of electric shock...

Страница 5: ...775 4382 USA toll free 1 608 831 4116 service etcconnect com ETC GmbH Germany Austria Switzerland Eastern Europe and Russia Technical Services Department Ohmstrasse 3 83607 Holzkirchen Germany 49 80...

Страница 6: ...3 Beacon Door Acrylic 7141A4050 1 1 2 Screw 6 32 X 3 8 Ph PH MS CP W Patch HW222 3 3 Screw 8 32 X 3 8 Ph PH MS CP W Patch HW377 3 3 CEM3 Backplane 1 8 8 screw spacer HW9343 3 3 3 CEM3 Beacon Assembly...

Страница 7: ...PAR LECTROCUTION Mettez le rack de gradation hors tension avant de retirer le CEM3 Ne retirez les modules de gradation ou de contr le que lorsque le rack est teint en suivant ces instructions ou selon...

Страница 8: ...ever these may refer to cable length and not dimmer outputs They should not be used as a reference to these instructions 4 Unscrew the backplane metal from the enclosure One screw in each side upper c...

Страница 9: ...d the enclosure wall avoiding any interference with other wires in the enclosure 3 Carefully route the ground wire to any open terminal in a grounding strip inside the enclosure Grounding terminal scr...

Страница 10: ...s of wires in one terminal block or using the DMX Thru connector If there is only one set of DMX wires in the connector and the DMX Thru is not used the enclosure is the last in the chain If there is...

Страница 11: ...to make the power and data connections Connect power and data to the backplane 5 Install the dimmer output ribbon cables Open the black retaining tabs for each connector until they are at a 45 angle...

Страница 12: ...ers to line up 13 Install one screw with a sleeve in each side upper corner of the backplane Transfer Panic Wiring if present If the enclosure had a panic connection in the previous backplane configur...

Страница 13: ...wn from inside the enclosure case The wire harness will only allow a few inches of movement 3 Note the orientation of the connector and unplug the wire harness from the old beacon PCB 4 Attach the wir...

Страница 14: ...ght Press and wipe with the removed paper backing to make sure the label is flat and smooth and properly adhered to the enclosure door 6 Repeat the above steps for all retrofitted enclosures Verify th...

Страница 15: ...rify the correct dimmer signal light as it illuminates 5 Verify that all sources of control DMX sACN Preset stations function correctly 6 Turn all dimmer circuit breakers back on Final Steps 1 Collect...

Страница 16: ...NY Orlando FL Los Angeles CA Austin TX Web etcconnect com Support support etcconnect com Contact etcconnect com contactETC 2021 Electronic Theatre Controls Inc Trademark and patent info etcconnect com...

Отзывы: