28
Register
Description
Read/Write
Modbus Settings
4:0051
Baud Rate
0 = 1200 bps
1 = 2400 bps
2 = 4800 bps
3 = 9600 bps
4 = 19,200 bps
5 = 38,400 bps
6 = 56,000 bps
7 = 115,200 bps
8 = 128,000 bps
9 = 256,000 bps
4:0052
Parity
0 = None
1 = Even
2 = Odd
4:0053
Data Bits
0 = 7 Data Bits
1 = 8 Data Bits
4:0054
Stop Bits
0 = 1 Stop Bit
1 = 2 Stop Bits
4:0055
Modbus Slave Station Address
1 - 247
4:0056
Modbus Protocol
0 = RTU
1 = ASCII
Kinetic Energy Configuration
4:0061
Plunger Mass
0
–
65.535 lbs (kg)
Where 65535 = 65.535
4:0062
Hard Arrival Velocity Threshold
0
–
65535 ft/min (m/min)
4:0063
–
4:0064 Hard Arrival Kinetic Energy Threshold
Floating-point format: 0
–
3.402823 × 10
38
ft-in (J)
4:0065
Consecutive Hard Arrival Alarm Threshold
0
–
65535
4:0066
Dangerous Arrival Velocity Threshold
0
–
65535 ft/min (m/min)