26
Register
Description
Read
Total Production Log
3:2501
–
3: 2506 Total Production Save Time
Date / Time Format
3:2507
Total Production Log Plunger Arrival Count
0 - 65535
3:2508
Total Production Log Maximum recorded
Velocity
0
–
1000 m/min (0
–
3281 ft/min)
3:2509
Total Production Log Minimum recorded
Velocity
0
–
1000 m/min (0
–
3281 ft/min)
Holding Registers
Table 12 - Available Holding Registers
Register
Description
Read/Write
General Controller Settings
4:0001
Modbus Write Time
The amount of time to wait after the last
written value before saving all changes to
the controller.
0
–
65535 seconds.
Writing zero (which is the default)
will save all changes as they are
made.
4:0002
–
4:0007 Controller Date/Time
Date/Time
4:0008
Daylight Savings Time configuration
0 = Disabled
1 = Enabled
4:0009
–
4:0010 Day Start Time
–
Start of the gas day.
Elapsed Time format: 0
–
86340
(00:00:
–
23:59)
When in HH:MM:SS format, only
Hours and Minutes are available.
4:0011
–
4:0030 Reserved
N/A