MicroVision FX
Connecting dimmers
To connect dimmers, first determine which of the following connectors
are appropriate and insert dimmer cables in appropriate connectors.
Then follow the instructions below to select the proper output
protocol(s) from the System Settings Menu. If your console is appropri-
ately configured,
MicroVision FX can output digital, AMX192 and analog
control signals simultaneously.
Caution: Your dimmer control common must be compatible with console
control common; they must either be the same level, or the dimmer
control common must float.
To select the proper output protocols from the System Settings Menu,
follow these steps:
1.
Press [Set Up].
2.
Select 7,
System settings
, and press [Enter].
3.
Verify that options 6, 7 and 8 indicate the proper dimmer settings for
your system.
Standard digital output protocols
DMX512 and D192 protocols are standard on
MicroVision FX. To select
the correct protocol, select 6,
Digital protocol
, and press [Enter]. Enter
1 to select DMX512, or 2 to select D192.
Optional output protocols
AMX192 and analog are optional output protocols that must be installed
at the factory. For more information, contact ETC.
AMX192
AMX192 is either enabled or disabled at all times. To select the proper
setting for your system, select 7,
AMX192
, and press [Enter]. Then
select either 1 to enable, or 2 to disable AMX192 dimmers.
Analog outputs
Analog outputs are either enabled or disabled at all times. To select the
proper setting for your system, select 8,
Analog outputs
, and press
[Enter]. Then select either 1 to enable, or 2 to disable analog outputs.