7
Wireless TimeClock Configuration Guide
Replace the Battery
The CR2032 battery is only used to maintain time in case of a power outage.
Estimated battery life is up to 10 years, depending on usage. To replace the
battery:
1. Remove the faceplate and unscrew the station from the electrical box to
access the back cover.
2. Unplug the pigtail connection from the receptacle, and the RP-SMA
connector, if using.
3. Insert a screwdriver into one of the holes on the side of the back cover
and pry carefully to free the side. Repeat to free the other side. The back
cover folds into three sections.
4. Remove the cover and insert the new battery under the clip with the
positive side (+) up.
5. Replace the cover, restore the connections, reinstall the station, safely
position the whip antenna, and attach the faceplate.
Note:
To avoid unwanted tampering, a two-gang locking cover
is sold separately through Echoflex, model no. SL-2.
Contact Echoflex for more information.