background image

ETC Installation Guide

ColorSource

®

 Linear Pearl v1.7

Corporate Headquarters 

 Middleton, Wisconsin, USA 

 Tel +608 831 4116 

Service (Americas) 

 

[email protected] 

London, UK 

 Tel +44 (0)20 8896 1000 

 Service: (UK)

 [email protected] 

Rome, IT 

 Tel +39 (06) 32 111 683 

 Service: (UK)

 [email protected] 

Holzkirchen, DE 

 Tel +49 (80 24) 47 00-0 

 Service: (DE)

 [email protected] 

Hong Kong 

 Tel +852 2799 1220 

 Service: (Asia)

 [email protected]

Web:

 etcconnect.com 

 © 2018 Electronic Theatre Controls, Inc. 

 Product information and 

specifications subject to change. 

 ETC intends this document to be provided in its entirety. 

 US Patents 8,384,294 . 8,403,523 . 8,593,074 . 8,633,649 . 8,723,450 . 8,878,455 . 9,041,308 

 EU Patents 2638781 . 6020110157302 

 All other patents pending.

7414M2120-1.7 

 Rev A 

 Released 2018-04 

Overview

The ColorSource Linear Pearl is an affordable LED fixture that provides a 
bright, variable white light. 

The fixture is available in three lengths:

• ColorSource Linear 1 (0.5 meter)
• ColorSource Linear 2 (1 meter)
• ColorSource Linear 4 (2 meter)

   

Note:

Features described in this document require the latest 

version of software. For information on updating fixture 

software, see 

Updating the fixture software

 on 

page 16

.

ColorSource Linear 1

Содержание ColorSource Linear Pearl

Страница 1: ...specifications subject to change ETC intends this document to be provided in its entirety US Patents 8 384 294 8 403 523 8 593 074 8 633 649 8 723 450 8 878 455 9 041 308 EU Patents 2638781 602011015...

Страница 2: ...ls WARNING Disconnect the fixture from power and DMX and allow it to cool before performing any cleaning and maintenance Note The ColorSource Linear Pearl is for indoor use only Note Maximum recommend...

Страница 3: ...rip curves when used with other equipment Requires power from a non dimmable source Inrush Linear 1 Linear 2 Linear 4 120V 35A 35 6A 67 5A first half cycle 240V 49A 85 6A 153A first half cycle Typical...

Страница 4: ...or secondary lenses are included with the fixture Use these spacers to hold the accessories in position when multiple lenses are used in the Linear 2 and Linear 4 fixtures The spacers are positioned b...

Страница 5: ...ntative and request part number W6538 for RJ45 to female XLR or part number W6539 for RJ45 to male XLR Connector locations Linear 1 Power connectors on one side of the fixture and data connectors on t...

Страница 6: ...nnector on the rear of the fixture 2 Make any power thru cable connections prior to applying a power source 3 Make any DMX connections and if the fixture is the last in a DMX line terminate the fixtur...

Страница 7: ...3 Tighten the trunnion locking knobs User interface The user interface allows you to set the start address of the fixture access the stand alone presets set the DMX control mode and set the Grouping m...

Страница 8: ...he DMX address for the fixture You can also use RDM for DMX addressing See Using RDM on page 19 Changing the DMX control mode You can set the DMX control mode for the fixture to one of three available...

Страница 9: ...fixture see Setting the DMX address on page 8 and the current DMX control mode see Changing the DMX control mode on page 8 For example if you set the DMX address on the fixture to 100 set the DMX mod...

Страница 10: ...o strobe Use values of 1 254 to increase the strobe rate from 1 per second up to 33 per second DMX Channel Variable Color Temperature Direct 1 Channel 1 Cell 1 Intensity Cell 1 Intensity C1 Intensity...

Страница 11: ...l Variable Color Temperature Direct 1 Channel 1 Cell 1 Intensity Cell 1 Intensity C1 Intensity 2 Color temperature Warm white C2 Intensity 3 Cell 2 Intensity Cool white C3 Intensity 4 Color temperatur...

Страница 12: ...50 105 106 2825 9 10 3550 58 4275 107 2850 11 3575 59 60 4300 108 109 2875 12 13 3600 61 62 4325 110 111 2900 14 15 3625 63 4350 112 2925 16 3650 64 65 4375 113 114 2950 17 18 3675 66 67 4400 115 116...

Страница 13: ...0 196 197 6150 233 234 5075 160 161 5625 198 6175 235 5100 162 163 5650 199 200 6200 236 237 5125 164 165 5675 201 202 6225 238 239 5150 166 5700 203 6250 240 5175 167 168 5725 204 205 6275 241 242 52...

Страница 14: ...g DMX set the desired levels 2 Press the Mode button to access the Presets menu 3 Using the Up and Down buttons navigate to the preset number that you want to re record 4 Press and hold the Mode butto...

Страница 15: ...to confirm your selection and return to the Presets menu The display will automatically return to the Presets menu after 10 seconds of inactivity and edits to the preset intensity will not be saved L...

Страница 16: ...r software version to all connected ColorSource fixtures You can push newer software versions from a connected fixture only on ColorSource fixtures running software v1 3 0 or newer Use UpdaterAtor to...

Страница 17: ...for secondary lenses are included with the fixture Use these spacers to hold the accessories in position when multiple lenses are used in the Linear 2 and Linear 4 fixtures 1 Loosen the thumbscrew on...

Страница 18: ...ctory contact your local dealer to set up a repair Screen toggles between and to indicate that the fixture has gone into over temperature protection mode to avoid damaging the fixture Once the fixture...

Страница 19: ...change the DMX address at the fixture however the fixture will return to sequential DMX addressing Linear 2 and Linear 4 fixtures in Group mode do not use sub devices RDM Values Manufacturer ID 0x657...

Страница 20: ...en toggles between and to indicate that the fixture has gone into over temperature protection mode to avoid damaging the fixture Once the fixture has self cooled the error will automatically clear Scr...