background image

ETC Installation Guide

D1 & D2 Series Drivers

D1 & D2 Series Drivers

Page 21 of 25

ETC

DMX512 from 
lighting console

DMX512

DMX512

ARC-TX1

Third party 
DMX devices

ArcSystem wired 
DMX luminaires

ArcSystem wireless 
luminaires

Note:

By default the TX1 DMX output is disabled. If you require DMX output from the

TX1, you must use the ArcSystem comissioning tool software to add DMX fixtures.

RDM Values

Manufacturer ID: 0x6574 (Electronic Theatre Controls)

Model IDs

Product Type

Description

Model ID

ArcSystem Pro One-Cell
or ArcSystem Pro One-Cell Small

D1 Driver

0x1201

D1 Emergency Driver

0x1301

ArcSystem Pro One-Cell High Output

D1 High Output Driver

0x1202

D1 High Output Emergency Driver

0x1302

ArcSystem Pro One-Cell Micro

D2 Driver

0x1203

D2 Emergency Driver

0x1303

Содержание ArcSystem Pro D1 HO

Страница 1: ...l ArcSystem products without ArcMesh can be configured for RDM control This manual provides step by step instruction on the installation of ArcSystem Pro One Cell luminaires D1 and D2 Series Drivers a...

Страница 2: ...is tilt beam angle options 19 24 37 60 ArcSystem Pro One Cell High Output external D1 HO driver required ideal for long throw 100 W full load power consumption fixed version recessed flush mount only...

Страница 3: ...MX control The D1 Driver provides up to 25 W to a single One Cell or One Cell Small luminaire The D1 HO Driver provides up to 100 W to a single One Cell High Output luminaire The D2 Driver supports on...

Страница 4: ...nsmitter with the highest MAC address acts as a master with the others assuming the role of backup For information on installing the ArcSystem TX1 Transmitter for use with ArcMesh installations see th...

Страница 5: ...all signal level of the system CAUTION If re broadcast mode is required use this feature in as few luminaires as possible to avoid unnecessary traffic on the network and possible system performance is...

Страница 6: ...input has been restored WARNING Do not mix 120 V and 277 V between the sense and emergency feeds AVERTISSEMENT Ne pas inverser les alimentations 120 V et 277 V entre les alimentations de d tection et...

Страница 7: ...readily accessible input power disconnect device installed ahead of your ArcSystem products WARNING RISK OF DEATH BY ELECTRIC SHOCK Failure to disconnect all power to the system before installation m...

Страница 8: ...luminaires or drivers temporarily or permanently may cause damage to the luminaires or drivers Preparing the Ceiling for Recessed Luminaires This section is specific to the recessed flush mounted vari...

Страница 9: ...Cell High Output luminaires plan the luminaire and driver locations around the required spacing listed below Install with minimum spacings between a Center to center of adjacent luminaires 609 6 mm 24...

Страница 10: ...tibles ou une isolation thermique NE PAS INSTALLER D ISOLATION MOINS DE 76 mm 3 po DE TOUTE PARTIE DE LA LAMPE OU DU DRIVER DISPOSITIF LECTRONIQUE DE PUISSANCE WARNING Adjustable ArcSystem Pro One Cel...

Страница 11: ...ne of DMX The following illustration shows an example of a linear ceiling installation with one luminaire for each D1 Series driver The cable between an ArcSystem Pro One Cell Series luminaire and its...

Страница 12: ...sible Wire and Terminal Specifications Terminal Connector Conduit Entry Wire Range Specifications Strip Length Torque Rating D1 power input line neutral ground in conduit Up to 6 mm2 10 AWG solid or s...

Страница 13: ...Driver Wiring of the driver consists of wiring power and data DMX to the driver for your luminaire and then running power out to the luminaire from the driver If you are installing emergency system dr...

Страница 14: ...l and tighten the screw 5 Insert the neutral wire typically white into the NEUTRAL N terminal and tighten the screw 6 Insert the line wire typically black into the LINE L terminal and tighten the scre...

Страница 15: ...res Data and Data plus an ISO ground common ETC recommends Cat5e or better minimum 24 AWG conductors terminated to T568B standard Up to 32 D1 D2 or D4 series drivers can be connected per DMX run DMX C...

Страница 16: ...duit to the driver There are four conduit knockouts available 5 Install Romex or nonmetallic screw clamp conduit connectors to output knockouts as needed Note Make sure that the flexible electrical su...

Страница 17: ...ETC Installation Guide D1 D2 Series Drivers D1 D2 Series Drivers Page 17 of 25 ETC Wiring D1 and D2 Series Emergency Drivers D1 Emergency Driver D1 HO Emergency Driver D2 Emergency Driver...

Страница 18: ...N terminal and tighten the screw 5 Connect the line wire typically black into the LINE L terminal and tighten the screw 6 Tug gently on the wires to ensure they are secure Connect Maintained Input Co...

Страница 19: ...ransmitter within the same plane as the luminaires Dual Redundancy Operation TX1 transmitters can be set up with dual redundancy allowing a backup transmitter to take control if the master transmitter...

Страница 20: ...ired DMX or a hybrid of the two making it a great solution for both new construction and retrofit situations ArcSystem RDM Systems can be controlled over wired DMX from a lighting console or ETC Conce...

Страница 21: ...DMX output from the TX1 you must use the ArcSystem comissioning tool software to add DMX fixtures RDM Values Manufacturer ID 0x6574 Electronic Theatre Controls Model IDs Product Type Description Mode...

Страница 22: ...Description 0x0344 Get returns an ASCII text string Output Response Time 0x0345 0x01 1000 ms 100 steps 0x02 900 ms 90 steps 0x03 800 ms 80 steps 0x04 700 ms 70 steps 0x05 600 ms 60 steps 0x06 500 ms...

Страница 23: ...of procedures included in the configuration process patching groups of luminaires to specific DMX channels assigning minimum and maximum dimming levels per group assigning power fail recovery options...

Страница 24: ...l components can be cleaned using compressed oil free air as described above or a clean micro fiber cloth The use of any liquid cleaning solution is not recommended Inspect all mounting hardware for w...

Страница 25: ...t may cause undesired operation ArcSystem wireless products contain FCC ID for US TYOJN5168M5 and Industry Canada IC ID IC 7438A CYO5168M5 Note Wireless capable ArcSystem products have been tested and...