Introduction

Congratulations on your purchase of ArcSystem products. ArcSystem is a family of overhead LED
products designed for installations where dimming, light quality, and ease of installation are
absolutely essential. With ArcSystem, you will experience perfectly smooth dimming from 100%
down to absolute zero. ArcSystem luminaires come in a variety of form factors, beam angles, and
color-temperature options, all with high-efficiency optics and an outstanding quality of light ideal for
any application.

ArcSystem products with ArcMesh can be controlled using wired DMX or the wireless ArcMesh
protocol. ArcSystem products without ArcMesh can be configured for RDM control. This manual
provides step by step instruction on the installation of ArcSystem Pro One-Cell luminaires, D1 and D2
Series Drivers, and full system integration. For information on installing ArcSystem Pro D4 Series
Drivers see

the ArcSystem D4 Series Drivers Installation Guide

at

etcconnect.com/ArcSystem

For

information on ArcSystem Pro Multi-Cell luminaires, see the

ArcSystem Pro Installation Manual

and

the

ArcSystem Pro Multi-Cell RDM Installation Guide

at

etcconnect.com/ArcSystem

.

All ETC manuals are available for download free of charge at

etcconnect.com

.

Safety

ArcSystem products are intended for professional use only. Read the entire manual before using this
equipment.

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions should always be followed including
the following:

READ AND FOLLOW ALL SAFETY
INSTRUCTIONS

Do not use outdoors.

Do not let power supply cords touch hot surfaces.

Do not mount near gas or electric heaters.

Equipment should be mounted in locations and at heights where it will not readily
be subjected to tampering by unauthorized personnel.

The use of accessory equipment not recommended by the manufacturer may cause
an unsafe condition.

Do not use this equipment for other than intended use.

SAVE THESE INSTRUCTIONS

Содержание ArcSystem Pro D1 HO

Страница 1: ...l ArcSystem products without ArcMesh can be configured for RDM control This manual provides step by step instruction on the installation of ArcSystem Pro One Cell luminaires D1 and D2 Series Drivers a...

Страница 2: ...is tilt beam angle options 19 24 37 60 ArcSystem Pro One Cell High Output external D1 HO driver required ideal for long throw 100 W full load power consumption fixed version recessed flush mount only...

Страница 3: ...MX control The D1 Driver provides up to 25 W to a single One Cell or One Cell Small luminaire The D1 HO Driver provides up to 100 W to a single One Cell High Output luminaire The D2 Driver supports on...

Страница 4: ...nsmitter with the highest MAC address acts as a master with the others assuming the role of backup For information on installing the ArcSystem TX1 Transmitter for use with ArcMesh installations see th...

Страница 5: ...all signal level of the system CAUTION If re broadcast mode is required use this feature in as few luminaires as possible to avoid unnecessary traffic on the network and possible system performance is...

Страница 6: ...input has been restored WARNING Do not mix 120 V and 277 V between the sense and emergency feeds AVERTISSEMENT Ne pas inverser les alimentations 120 V et 277 V entre les alimentations de d tection et...

Страница 7: ...readily accessible input power disconnect device installed ahead of your ArcSystem products WARNING RISK OF DEATH BY ELECTRIC SHOCK Failure to disconnect all power to the system before installation m...

Страница 8: ...luminaires or drivers temporarily or permanently may cause damage to the luminaires or drivers Preparing the Ceiling for Recessed Luminaires This section is specific to the recessed flush mounted vari...

Страница 9: ...Cell High Output luminaires plan the luminaire and driver locations around the required spacing listed below Install with minimum spacings between a Center to center of adjacent luminaires 609 6 mm 24...

Страница 10: ...tibles ou une isolation thermique NE PAS INSTALLER D ISOLATION MOINS DE 76 mm 3 po DE TOUTE PARTIE DE LA LAMPE OU DU DRIVER DISPOSITIF LECTRONIQUE DE PUISSANCE WARNING Adjustable ArcSystem Pro One Cel...

Страница 11: ...ne of DMX The following illustration shows an example of a linear ceiling installation with one luminaire for each D1 Series driver The cable between an ArcSystem Pro One Cell Series luminaire and its...

Страница 12: ...sible Wire and Terminal Specifications Terminal Connector Conduit Entry Wire Range Specifications Strip Length Torque Rating D1 power input line neutral ground in conduit Up to 6 mm2 10 AWG solid or s...

Страница 13: ...Driver Wiring of the driver consists of wiring power and data DMX to the driver for your luminaire and then running power out to the luminaire from the driver If you are installing emergency system dr...

Страница 14: ...l and tighten the screw 5 Insert the neutral wire typically white into the NEUTRAL N terminal and tighten the screw 6 Insert the line wire typically black into the LINE L terminal and tighten the scre...

Страница 15: ...res Data and Data plus an ISO ground common ETC recommends Cat5e or better minimum 24 AWG conductors terminated to T568B standard Up to 32 D1 D2 or D4 series drivers can be connected per DMX run DMX C...

Страница 16: ...duit to the driver There are four conduit knockouts available 5 Install Romex or nonmetallic screw clamp conduit connectors to output knockouts as needed Note Make sure that the flexible electrical su...

Страница 17: ...ETC Installation Guide D1 D2 Series Drivers D1 D2 Series Drivers Page 17 of 25 ETC Wiring D1 and D2 Series Emergency Drivers D1 Emergency Driver D1 HO Emergency Driver D2 Emergency Driver...

Страница 18: ...N terminal and tighten the screw 5 Connect the line wire typically black into the LINE L terminal and tighten the screw 6 Tug gently on the wires to ensure they are secure Connect Maintained Input Co...

Страница 19: ...ransmitter within the same plane as the luminaires Dual Redundancy Operation TX1 transmitters can be set up with dual redundancy allowing a backup transmitter to take control if the master transmitter...

Страница 20: ...ired DMX or a hybrid of the two making it a great solution for both new construction and retrofit situations ArcSystem RDM Systems can be controlled over wired DMX from a lighting console or ETC Conce...

Страница 21: ...DMX output from the TX1 you must use the ArcSystem comissioning tool software to add DMX fixtures RDM Values Manufacturer ID 0x6574 Electronic Theatre Controls Model IDs Product Type Description Mode...

Страница 22: ...Description 0x0344 Get returns an ASCII text string Output Response Time 0x0345 0x01 1000 ms 100 steps 0x02 900 ms 90 steps 0x03 800 ms 80 steps 0x04 700 ms 70 steps 0x05 600 ms 60 steps 0x06 500 ms...

Страница 23: ...of procedures included in the configuration process patching groups of luminaires to specific DMX channels assigning minimum and maximum dimming levels per group assigning power fail recovery options...

Страница 24: ...l components can be cleaned using compressed oil free air as described above or a clean micro fiber cloth The use of any liquid cleaning solution is not recommended Inspect all mounting hardware for w...

Страница 25: ...t may cause undesired operation ArcSystem wireless products contain FCC ID for US TYOJN5168M5 and Industry Canada IC ID IC 7438A CYO5168M5 Note Wireless capable ArcSystem products have been tested and...

Отзывы: