ETC Installation Guide

ArcSystem Pro Multi-Cell

ArcSystem Pro Multi-Cell

Page 17 of 24

ETC

Connect the Maintained Input

1.

See

Wire and Terminal Specifications on page 10

for specification of wire and strip

length. Prepare wires accordingly.

2.

Remove the screws securing the wiring compartment cover to the fixture. The cover is
grounded to the enclosure by a tether. Set the screws aside.

3.

Terminate ground.
a.

Locate the WAGO connector on the ground wire (green) connected to the bottom of the
wiring compartment (

).

b.

Run a ground wire (typically green/yellow) through conduit to a free position on the
WAGO connector.

c.

Lift up the orange clip, insert the ground wire, and press the clip down onto the wire.

d.

Tug gently to make sure the wire is secure.

4.

Terminate neutral to the Maintained input.
a.

Locate the WAGO connector on the neutral wire (white) from the input labeled
Maintained.

b.

Run a neutral wire (typically white or grey) through conduit to a free position on the
WAGO connector.

c.

Lift up the orange clip, insert the neutral wire, and press the clip down onto the wire.

d.

Tug gently to make sure the wire is secure.

5.

Terminate line (hot) to the Maintained input.
a.

Locate the WAGO connector on the line (hot) wire (black) from the input labeled
Maintained.

b.

Run a line (hot) wire through conduit to a free position on the WAGO connector.

Note:

Line (hot) wire color varies based on voltage and region but is typically black,

brown, orange, or yellow.

c.

Lift up the orange clip, insert the line wire, and press the clip down onto the wire.

d.

Tug gently to make sure the wire is secure.

Connect the Sense Input

1.

Make sure power is off at the main circuit breaker.

2.

See

Wire and Terminal Specifications on page 10

for specification of wire and strip

length. Prepare wires accordingly.

3.

Terminate ground.
a.

Locate the WAGO connector on the ground wire (green) connected to the bottom of the
wiring compartment.

a.

Run a ground wire (typically green/yellow) through other conduit to a free position on the
WAGO connector.

b.

Lift up the orange clip, insert the ground wire, and press the clip down onto the wire.

c.

Tug gently to make sure the wire is secure.

4.

Terminate neutral to the Sense input.
a.

Locate the WAGO connector on the neutral wire (white) from the input labeled Sense.

b.

Run a neutral wire (typically white or grey) through conduit to a free position on the
WAGO connector.

c.

Lift up the orange clip, insert the neutral wire, and press the clip down onto the wire.

d.

Tug gently to make sure the wire is secure.

Содержание ArcSystem ARCP2

Страница 1: ...ture options all with high efficiency optics and an outstanding quality of light ideal for any application This manual provides step by step instruction on the installation and RDM configuration of Ar...

Страница 2: ...nd RDM ARCP8 100 240 V or 100 277 V Pro Eight Cell ARCP8RDM 100 240 V or 100 277 V Pro Eight Cell RDM ArcSystem Multi Cell Emergency Fixtures with Integral Drivers Model Description ARCPE2 100 240 V o...

Страница 3: ...with IEC connector or 100 277 V hard wired input options Emergency 100 125 V with NEMA 5 15 connectors or 100 277 V hard wired input options linear and square yoke mount round and pendant options beam...

Страница 4: ...ETC Installation Guide ArcSystem Pro Multi Cell ArcSystem Pro Multi Cell Page 4 of 24 ETC...

Страница 5: ...rd wired to emergency certified drivers to be considered for UL924 certification Note Emergency fixtures must be installed in a high bay situation Note The number of designated emergency lamps and the...

Страница 6: ...ored WARNING Do not mix 120 V and 277 V between the sense and emergency feeds AVERTISSEMENT Ne pas inverser les alimentations 120 V et 277 V entre les alimentations de d tection et de secours WARNING...

Страница 7: ...graves ou la mort De energize main feed to ArcSystem and follow appropriate Lockout Tagout procedures as mandated by NFPA 70E It is important to note that electrical equipment such as breaker panels...

Страница 8: ...DMX run RJ45 Pinout Information Pin Description 1 Data 2 Data 7 8 ISO ground common Four cell square fixture shown DMX In and Thru connections Power switch Power connection Installation Procedure 1 A...

Страница 9: ...mm or 1 2 13 in with the two provided screws 2 Attach the fixture to the installed threaded rod 3 Plug in the provided power cable 4 If using hard wired DMX plug in the RJ45 connector into the DMX In...

Страница 10: ...cSystem 100 277 V fixture on a power distribution system with reliably identified earthed neutral and install a maximum 20 A circuit breaker on the line conductor ArcSystem 100 277 V fixtures and driv...

Страница 11: ...Mounting hardware and installation location must support the weight of the fixture conduit hardware and all cable required for installation 1 Make sure power is off at the main circuit breaker 2 Atta...

Страница 12: ...ed with three two position WAGO connectors ETC part number J4717 WAGO part number 221 412 See Installing 100 277 V Emergency Multi Cell Fixtures on page 15 for more information about wiring for emerge...

Страница 13: ...he wire is secure 5 Terminate line hot a Locate the WAGO connector on the line hot wire black from the input b Run a line hot wire through conduit to a free position on the WAGO connector Note Line ho...

Страница 14: ...rgency fixture shown Actual cable length is 2 1 m 7 ft ArcSystem 100 125 V multi cell emergency systems include Pro Two Cell Pro Four Cell Square Pro Four Cell Linear Pro Four Cell Round and Pro Eight...

Страница 15: ...wiring compartment B conduit entry for 1 2 in conduit C DMX in and thru D knockout for 1 2 in conduit With the exception of power input terminations ArcSystem 100 277 V emergency system installation r...

Страница 16: ...upplied with one three position WAGO ETC part number J4629 WAGO part number 221 413 and four two position WAGO connectors ETC part number J4717 WAGO part number 221 412 Factory Wire Colors Color Type...

Страница 17: ...Maintained input a Locate the WAGO connector on the line hot wire black from the input labeled Maintained b Run a line hot wire through conduit to a free position on the WAGO connector Note Line hot w...

Страница 18: ...k that all wires are terminated properly and secure in their terminals 2 Tuck wiring and WAGO connectors inside wiring compartment Replace the wiring compartment cover using the screws set aside previ...

Страница 19: ...each DMX line Wireless DMX control requires a TX1 Transmitter and fixtures with the wireless ArcMesh transceiver For wireless DMX installation see the ArcSystem Installation Manual available from etc...

Страница 20: ...LEDs with a single DMX address The multi channel personality controls individual LEDs or pairs of LEDs with up to four channels as shown below Note You cannot manually assign DMX addresses to each cha...

Страница 21: ...2 or 3 Set to 1 is the Default Tungsten Curve aka D04A Set to 2 is Linear Set to 3 is Square Law Curve Description 0x0344 Get returns an ASCII text string Output Response Time 0x0345 0x01 1000 ms 100...

Страница 22: ...ng any cleaning and maintenance AVERTISSEMENT D brancher la lampe de son alimentation et du DMX et la laisser refroidir avant d effectuer un nettoyage ou un entretien WARNING Circuits that are install...

Страница 23: ...ult in serious injury or death AVERTISSEMENT RISQUE DE MORT PAR D CHARGE LECTRIQUE N gliger de d brancher toutes les sources d alimentation du syst me avant l installation l entretien le nettoyage ou...

Страница 24: ...ication DMX Link LED Slow flash normal operation DMX broadcast is being received and DMX data is not changing Solid On active DMX signal is being received Solid On DMX is present DMX Status LED Steady...

Отзывы: