THE PUMP JUST SWITCHED ON GIVE TWO OR THREE INJECTION AND THEN STOP
Check the Remote Control Menù and the Alarm Menù for proper setting. If setting are correct, reset the pump follow-
ing the procedure described in chapter 6.3.
➒
IN CASE THE ADDITIVE LEVEL IS BELOW THE LEVEL PROBE AND THE LEVEL ALARM IS STILL OFF
Check the level switch connection, short circuit poles connector (Section 3.2 pos. 2), in case the alarm is on, repla-
ce the switch; if the alarm is off, contact manufacturer customer service, dealer or distributor.
8.3 RESTORATION OF DEFAULT PARAMETERS
If for any reasons the user wants to erase all the parameters and re-start the pump to the default setting, press the
START/STOP (9) button and contemporarily press PREVIOUS (8) and NEXT (2) arrows.
When START/STOP button is pressed the pump will reset to default setting.
This will cancel all set parameters.