The values listed above are intended to be within a tolerance of +/- 5%. They were obtained by a series of test
performed on similar equipments with water at temperature of 20°C.
Overall dimensions
Fig. 1 - Dimensions in mm. Plate for wall mounting.
Material in contact with the additive
In the standard configuration the pumps of the "eOne" series are supplied with the following materials:
Pump Head Membrane
Seals
Valves
Connections
Pipes
Pump
Casing
PVDF
PTFE
TFE/P
CERAMIC
TFE/P
PVDF
PE / PVC
PP
INSTALLATION
Introduction
This section describes steps for installing the pump, hoses and wiring. Please read this instruction before starting any
activity.
Follow these guidelines when installing the pump:
•
Make sure the pump is powered off and any other related equipment before starting any activity.
•
In case of any unusual events or warning signs, stop immediately. Start again only when you are absolutely
sure that any possible problem has been solved.
•
Do not install the pump in hazardous environments such as at risk of fire or explosion.
•
Avoid risk of electrical type and or fluid leakage. Never use a damaged or defective pump.