INSTALLATION
Introduction
This section describes steps for installing the equipment and wiring. Please read this instruction before starting any
activity.
Follow these guidelines when installing the equipment:
•
Make sure the equipment is powered off and any other related equipment before starting any activity.
•
In case of any unusual events or warning signs, stop immediately. Start again only when you are absolutely
sure that any possible problem has been solved.
•
Do not install the equipment in hazardous environments such as at risk of fire or explosion.
•
Avoid risk of electrical type and or fluid leakage. Never use a damaged or defective equipment.
Water meter signal splitter installation
Install the equipment away from heat sources, in a dry place and at a maximum ambient temperature of 104°F. Locate
the equipment at maximum distance of 20 meters (cable length) from water meter and other 20 meters from pumps and
controller.
Typical full installation
In the following figure is an example of complete installation with three pumps and one controller. You can connect any
type of proportional dosing pump (for example e128 or eMP pump) and any type of controller with at least an analog input
Fig. 3
–
Typical full installation