Etatron America WATER METER SIGNAL SPLITTER Скачать руководство пользователя страница 10

10 

ENGLISH

 

 

 

MAINTENANCE 

Ordinary  

An Ordinary and accurate maintenance with a programmed check, guarantee the preservation over time and the proper 

functioning of the systems. Therefore, we recommend that the user follow our advice and maintenance of a service contract 

and assistance programmed with one of our Technical Support Centre. 

Check  at  least  every  6  months  functioning  of  the  equipment.  In  case  of  intensive  use,  you  should  increase  the 

frequency of these controls. 

Extraordinary 

 All components of our supplies are chosen and tested according to strict principles of selection, and then provide, for a 

long time, reliability and functionality in our devices. 

TROUBLESHOOTING 

Given the sturdiness of the system, mechanical failures do not occur. Any intervention or repair within the equipment 

must be carried out by qualified and authorised personnel. 

In  the  event  of maintenance  and/or technical work,  always  make  sure  that  the  equipment  is  disconnected from the 

electrical mains and that you are wearing protective clothing and equipment (gloves and safety goggles). 

 

FAULT 

SOLUTION 

The equipment is not power up 

 

Check if the plug is properly connected 

 

Check the fuse (0,315 A) 

 

Electronic board blown due to overvoltage, no earthing, etc.: replace the board 

The equipment does not transmit 

output pulses 

 

Check the board, if blown replace it 

The equipment does not receive 

input pulses 

 

Check if the water meter works properly 

 

Check if the cable is wired properly 

Содержание WATER METER SIGNAL SPLITTER

Страница 1: ...Water Meter Signal Splitter OPERATING INSTRUCTIONS AND MAINTENANCE ...

Страница 2: ......

Страница 3: ... handling 5 Assembly 5 Dismantlement 5 Warranty 5 WATER METER SIGNAL SPLITTER eMP 6 Operating principle 6 Technical features 6 Reference Standards 6 Overall dimensions 6 INSTALLATION 7 Introduction 7 Water meter signal splitter installation 7 Typical installation 7 Electrical connections 8 OPERATING INSTRUCTIONS 9 Front Panel 9 LED description 9 MAINTENANCE 10 Ordinary 10 Extraordinary 10 TROUBLES...

Страница 4: ...ust comply with the rules in force in the country where it is installed The use of any electrical device requires compliance with some basic rules In particular do not touch the equipment with wet or damp hands or feet do not handle the equipment with bare feet do not leave the unit exposed to the elements rain sun etc Protect equipment chemicals from freezing temperatures do not allow the equipme...

Страница 5: ...ts correct use The manufacturer cannot be considered responsible for any damage derived from improper erroneous and unreasonable use Shipping and handling Shipping must be performed in the same orientation as indicated on the packaging Shipping using any means even if delivered free to the customer is considered at the purchaser s risk Claims for missing material must be made within 10 days from g...

Страница 6: ...ded range 90 260 Volt 50 60 Hz Prewired with 125 V nema 5 15P plug IP65 protection level Environmental conditions closed environment altitude up to 2000 m ambient temperature from 41 F to 104 F maximum relative humidity 80 up to a maximum of 88 F linear decrease down to 50 at 104 F Classification with respect to protection against indirect contacts CLASS I the equipment is supplied with an electri...

Страница 7: ...vironments such as at risk of fire or explosion Avoid risk of electrical type and or fluid leakage Never use a damaged or defective equipment Water meter signal splitter installation Install the equipment away from heat sources in a dry place and at a maximum ambient temperature of 104 F Locate the equipment at maximum distance of 20 meters cable length from water meter and other 20 meters from pu...

Страница 8: ...trical connections The following figure describes the electrical connections Fig 2 Wiring If you open the front cover pay attention to the insulation of the cable terminals If necessary restore it to avoid short cuts ...

Страница 9: ...R 3 Yellow flashing LED output pulse to PUMP 1 4 Yellow flashing LED output pulse to PUMP 2 5 Yellow flashing LED output pulse to PUMP 3 LED description a LED 1 light up green when the equipment is power on b LED 1 flashing RED when the equipment receives a water meter pulse c LED 2 3 4 and 5 flashing YELLOW when the equipment transmits a pulse to OUT 1 2 3 and 4 ...

Страница 10: ...y and functionality in our devices TROUBLESHOOTING Given the sturdiness of the system mechanical failures do not occur Any intervention or repair within the equipment must be carried out by qualified and authorised personnel In the event of maintenance and or technical work always make sure that the equipment is disconnected from the electrical mains and that you are wearing protective clothing an...

Страница 11: ......

Страница 12: ...WDMU00216ML1A 08 2017 ETATRON AMERICA Dilution Solutions Inc 2090 Sunnydale Blvd Clearwater FL 33765 Telephone 727 451 1198 FAX 727 451 1197 ...

Отзывы: